![Carmanah M650H Скачать руководство пользователя страница 75](http://html.mh-extra.com/html/carmanah/m650h/m650h_user-manual_2559186075.webp)
© 2014, Carmanah Technologies Corporation. June 2014. 61249_M650H_User_Manual_RevC
M650H USER MANUAL
75
RANGE (NM)
EFFECTIVE INTENSITY (cd)
T = 0.74
T = 0.85
4.3
46
26
4.4
50
27
4.5
54
29
4.6
58
31
4.7
62
33
4.8
67
34
4.9
72
37
5.0
77
39
5.1
83
41
5.2
89
43
5.3
95
46
5.4
102
48
5.5
109
51
5.6
116
53
5.7
124
56
5.8
132
59
5.9
141
62
6.0
150
65
6.1
160
69
6.2
171
72
6.3
181
76
6.4
193
80
6.5
205
83
6.6
218
87
6.7
232
91
6.8
246
96
6.9
261
100
7.0
277
105
Effective Intensity
The effective intensity of a flashing lantern comes
from the following calculation known as Schmidt-
Clausen or Blondel-Rey documented in IALA
Recommendations E-122 (2001) and E-200-4
(2008). This method is valid for the rectangular,
non-fluctuating flash profiles below the flicker fusion
frequency (60 Hz) used by Carmanah lanterns.
I
e
=
I
p
x F
C + F
I
e
= effective intensity (cd)
I
p
= peak intensity (cd)
C = visual time constant (s)
F = flash duration (s)
The visual time constant is 0.2 s for a lantern at night-
time.