42
User Tasks
Restoring the Default Configuration
If you accidentally change a setting while customizing
your lantern’s settings, you can restore the lantern to
its previous configuration.
Restoring the configuration changes the following
settings (if they’re different from the current values):
Flash Code, Effective Intensity, Automatic Light
Control, Day to Night Transition, Night to Day
Transition, Switch Mode, and User Passcode.
NOTE
Latitude/Longitude, Transmissivity,
and Distributor Passcodes won’t
change.
To restore the configuration:
1. Remove the lantern’s Bottom Cover and plug the
USB cable into the USB port.
2. Connect the other end of the USB cable to an
empty USB port on your computer.
3. Open 650DM on your computer. 650DM may take
a moment to find and connect to the lantern.
4. Click
Configuration
on the Bottom Bar. The
Configuration screen appears.
5. Click
Restore Defaults
(on the right side of
the screen). The lantern’s current settings are
replaced with the settings last programmed by
your Distributor or Carmanah Manufacturing.
Using the Derived Values
Derived Values are calculated based on the settings
you select for your lantern. The values described in
the following table are calculated from the following
settings: Flash Code, Effective Intensity, Day to Night
Transition, Night to Day Transition, the Latitude and
Longitude, and Transmissivity.
If you change any of these settings, 650DM calculates
the effects of your changes on the lantern, and
displays the results in the Derived Values area of the
Configuration Page.
Note that until you use the
Send Settings to Device
button, the values in the
Device
columns remain
unchanged. This allows you to compare the lantern’s
current derived values with those resulting from the
settings currently entered in the
Setting
columns in
the
Device Function
area.