Step 18
Flush Bearing Air Jets with an
aerosol electronic contact cleaner
as shown in Figure 1-18
Solvent Flush Ports:
Apply aerosol feed tube to bearing air port as
shown. The hole on the opposite side need to be
blocked. Use a small cloth or a piece of rubber.
See Figure 1-18A on where Solvent should exit
(bearing air ports).
Figure 1-18A
Figure 1-18B
Flush Bearing Air Jets:
Apply an aerosol electronic contact clean-
er to bearing air-port and observe to see
if solvent passes through all bearing air
ports. See solvent stream shown in Figure
1-18B. Holes must be free of debris to
assure optimal performance.