Options
Vita II
60
Operating manual
11.18
After selection of desired Dispenser I/O operating mode, press key
to select additional parameters.
First value
= Indication of the current sensor level. This indication
is for checking purposes and cannot be modified.
Second value
= Indication if a label (value = 1) or if no label (value =
0) was found. This indication is for checking
purposes if the set switch level leads to a correct
label recognition.
Third value
= Indication of switch level (Default: 1.2).
Fourth value
= Transmission power of label sensor [1..255]
Depending on label material (color) the sensor level
can be adapted in order to permit a safe label
recognition (Default: 80).
NOTICE!
The modification of this value is only taken into consideration
for the operating modes
Photocell
and
Photocell continuous
.
Press key
to arrive the next parameter.
Definition of port functions:
2 sign show the current setting for each port.
Port
1 2 3 4 5 6 7 8
because of space reasons, the port number cannot be indicated)
The first sign specifies the following:
I
= Port operates as Input
O
= Port operates as Output
N
= Port has no function (not defined)
These settings cannot be modified.
The second sign specifies the following:
+
= Active signal level is 'high' (1)
−
= Active signal level is 'low' (0)
x
= Port is deactivated
&
= Function is executed at each change of the signal level
s
= Status can be enquired/influenced
*
by interface
=
The printer-internal function is deactivated.
The modification of the signal level is only taken into consideration for
the operating modes I/O static, I/O dynamic, I/O static continuous and
I/O dynamic continuous.
*
in connection with Netstar PLUS
Additional parameters
for Dispenser I/O
Dispenser photocell
I/O Port 1-8 and
I/O Port 9-16