![Carl Valentin Vita II 103/8 T Скачать руководство пользователя страница 77](http://html1.mh-extra.com/html/carl-valentin/vita-ii-103-8-t/vita-ii-103-8-t_operating-manual_2558351077.webp)
Vita II
Maintenance and cleaning
11.18
Operating manual
77
9
Maintenance and cleaning
DANGER!
Risk of death by electric shock!
Before opening the housing cover, disconnect the
device from the mains supply and wait for a
moment until the power supply unit has discharged.
NOTICE!
When cleaning the label printer, personal protective equipment
such as safety goggles and gloves are recommended.
Maintenance task
Frequency
General cleaning (see section
9.1, page 78).
As necessary.
Cleaning transfer ribbon
drawing roller (see section 9.2,
page 79).
Each time the transfer ribbon is
changed or when the printout is
adversely affected.
Cleaning print roller (see section
9.3, page 79).
Each time the label roll is
changed or when the printout and
label transport are adversely
affected.
Cleaning printhead (see section
9.4, page 80).
Direct thermal printing:
Each time the label roll is
changed.
Thermal transfer printing:
Each time the transfer ribbon is
changed or when the printout is
adversely affected.
Cleaning label photocell (see
section 9.5, page 81).
When exchanging the label roll.
Replacing printhead (see
section 9.6, page 82).
In case of errors in printout.
NOTICE!
The handling instructions for the use of Isopropanol (IPA) must
be observed. In the case of skin or eye contact, immediately
wash off the fluid thoroughly with running water. If the irritation
persists, consult a doctor. Ensure good ventilation.
Maintenance