Vita II
Function menu
11.18
Operating manual
51
6.11 Service functions
NOTICE!
So that the distributor res. the printer manufacturer in case of
service can offer fast support, the printer is equipped with the
menu
Service functions
.
Necessary information such as selected parameters can be
taken directly from the printer. More details such as version of
firmware or font are shown from the
Main menu.
Switch on the label printer and the display shows the main menu.
Press key
to access the function menu.
Press key
as long as you arrive the
Service functions
menu.
Press key
to select the menu.
Indication of label parameters in Volt.
A:
Indication of minimum value.
B:
Indication of difference between minimum and maximum value.
C:
Indication of trigger level. The value is ascertained while measuring
and can be changed.
Press key
to arrive the next menu item.
This function enables definition of photocell levels.
In case of problems while positioning or measuring of label, levels for
label photocell can be set manually. Make sure that a large hub as
possible (above the label >3 V, above the gap <1 V) is set.
Press key
to arrive the next menu item.
DLS:
Indication of transmission photocell level in Volt.
RLS:
Indication of reflexion photocell level in Volt.
SLS:
Indication of peel off photocell level in Volt.
TR:
Indication of transfer ribbon photocell status
(either 0 or 1).
H:
Indication of printhead position.
0 = printhead down
1 = printhead up
Press key
to arrive the next menu item.
D:
Indication of printhead attainment in meters.
G:
Indication of printer attainment in meters.
Press key
to arrive the next menu item.
To achieve a high print quality, the indicated Ohm value must be set
after an exchange of printhead.
Label parameters
Photocell configuration
Photocell parameters
Paper counter
Heater resistance