Vita II
Technical data
11.18
Operating manual
19
Figure 3
Port 1 to Port 16 = Assignment for I/O Profile
Std_Label
Identification
Pin
Description / Function
Port 1
10
Print start and cut (Input)
Port 2
1
Reprint last printed label (Input)
Port 3
11
Counter Reset (Input)
Port 4
2
Option applicator only:
Start application (Input)
Port 5
12
Error reset (Input)
Port 6
3
Cancel all print jobs (Input)
Port 7
13
No function
Port 8
4
No function
Port 9
15
Error (Output)
Port 10
6
Print order activ (Output)
Port 11
16
Dispenser photocell:
Label exists at dispenser photocell (Output)
Port 12
7
Single print (Output)
Port 13
17
Ready (Output)
Port 14
8
Option applicator only:
Ready for application (Output)
Port 15
18
Option scanner only
Bar code not readable (Output)
Port 16
9
Prior warning for transfer ribbon end (Output)
COM/VDC
for Inputs
19
Common reference potential of all control inputs. 'COM/VDC for
Inputs' is usually connected with the (-) terminal of the control voltage
and the control inputs are switched to active (+).
By means of the option '2nd LED', 'COM/VDC for Inputs' can
optionally be connected with the (+) terminal of the control voltage.
Then, the control inputs are switched to active (-).
VDC for
Outputs
20
Common supply connection of all control outputs. 'VDC for Outputs'
must be connected with the (+) terminal of the control voltage.
Never leave 'VDC for Outputs' open even if no output is used.
COM for
Outputs
5,14
21,22
Common reference potential of all control outputs. 'COM for Outputs'
must be connected with the (-) terminal of the control voltage.
Never leave 'COM for Outputs' open even if no output is used.
GND-PE
23,24
'GND-PE' is the reference potential of the '+5 VDC EXT' and '+24
VDC EXT' voltages provided by the printer system.
'GND-PE' is printer internally connected with protective earth (PE).
Configuration of