Operation
Applicator APL 100
46 Operating
Manual
11/13
Test Mode Using the Pre-dispense Key without Print Job
This method allows to check the labelling process with real print data
using the pre-dispense key (1, Figure 28).
Send a print job.
The test mode is executed in two half-cycles.
Press the pre-dispense key (1, Figure 28).
Half-cycle 1
A label is printed. The vacuum at the pad as well as the
supporting air (blow tube) are switched on. After the label has
been picked up by the pad, the supporting air is switched off.
Press the pre-dispense key (1, Figure 28) again.
Half-cycle 2
The pad is moved to the labelling position. A sensor signals
when the labelling position is reached. The vacuum is switched
off and the label is placed onto the product. Then, the pad is
moved back into the starting position.
If the label is manually removed from the pad after the first half cycle,
the half cycle 1 will be repeated when the pre-dispense key is pressed
again.
NOTICE!
Please use this method to adjust the appropriate dispenser
offset in the label design software.