Applicator APL 100
Configuration
11/13 Operating
Manual
31
Press key
to arrive the next parameter.
This menu serves for the applicator setup as well as for error tracing.
Input signals of the applicator can be monitored and output signals
can be set or reset separately. With keys
and
the
corresponding output for setting and/or resetting the output signals
can be selected. With keys
and
the corresponding output can
be set or reset.
Input signals
I1 =
Pre-dispense key (1 = key pressed, 0 = key not pressed)
I2 =
Final position up (1 = pad in final position up,
0 = pad not in final position up)
I3 =
Final position down (1 = pad in final position down,
0 = pad not in final position down)
I4 =
Compressed air (1 = compressed air available,
0 = no compressed air available)
I5 =
Vacuum (1 = vacuum at pad available, 0 = no vacuum at pad
available)
Output signals
1 =
Move pad downwards (1 = On, 0 = Off)
2 =
Move pad upwards (1 = On, 0 = Off)
3 =
not assigned
4 =
not assigned
5 =
Blowing air (1 = On, 0 = Off)
6 =
Supporting air (1 = On, 0 = Off)
7 =
Vacuum pad (1 = On, 0 = Off)
Press key
to arrive the next parameter.
This parameter is only active if the operating mode 'stamp on' is
selected. The time period can be adjusted while the pad is kept in the
labelling position for applying the label onto the goods.
Input/Output
Pressure time
Содержание APL 100
Страница 1: ...APL 100 Operating Manual ...
Страница 18: ......
Страница 26: ......
Страница 38: ......
Страница 48: ......
Страница 52: ......
Страница 53: ...Applicator APL 100 Declaration 11 13 Operating Manual 53 12 Declaration 12 1 Extended Declaration ...
Страница 54: ...Declaration Applicator APL 100 54 Operating Manual 11 13 12 2 EC Declaration of Conformity ...
Страница 57: ......