4.7 Connections
5
4
3
2
1
Figure 14
1. Prepare the printer connections to the power supply and to the
computer (see operating manual of the label printer).
2. Close the shutoff valve (3 / lever at the valve is turned across the
air flow direction).
3. Connect the applicator to the compressed air supply.
The connector (2) for the compressed air supply is located at the
rear of the service unit. The connector is suitable for a 1/4"
coupling plug (1) or a tube with a diameter of 8 mm.
4. The air pressure for operating the applicator is pre-adjusted to
0,5 MPa (5 bar). Check the pressure at the manometer (5) of the
service unit. Correct the adjustment if necessary:
Pull knurled knob (4) up.
Turn knob to tune required operating pressure of 5 bar.
Push knob down.
5. Open the shutoff valve (3 / lever is turned in the air flow direction).
6. Switch on the power supply of the printer.
CAUTION!
The pad will immediately be moved in the starting position.
Danger of crushing to hand and fingers by the moving pad.
Do not reach into the zone of the moving pad.
Keep long hair, loose clothes and jewellery distant
from the zone of the moving pad.
Danger of striking by the moving rods.
Do not reach or bend into the zone of the moving rods.
Содержание APL 100
Страница 1: ...APL 100 Operating Manual ...
Страница 18: ......
Страница 26: ......
Страница 38: ......
Страница 48: ......
Страница 52: ......
Страница 53: ...Applicator APL 100 Declaration 11 13 Operating Manual 53 12 Declaration 12 1 Extended Declaration ...
Страница 54: ...Declaration Applicator APL 100 54 Operating Manual 11 13 12 2 EC Declaration of Conformity ...
Страница 57: ......