2. INSTALLATION
2.1 DIN rail assembly and dimensions
EVD evolution twin is supplied with screen-printed connectors to simplify
wiring.
VBA
T
G0
G
E
X
V connection
Power Supply
Relay
NO 1
COM 1
4
2
3
1
GND
V REF
S1
S2
S3
S4
DI1
DI2
Analog – Digital Input
Network
GND
Tx/Rx
EV
D
evolution
70
60
110
45
twin
49
Fig. 2.a
2.2 Description of the terminals
VBA
T
G0
G
E
X
V connection
A
P
ower
S
upply
R
elay
A
NO A1
COM A
4
2
3
1
GND
V REF
S1
S2
S3
S4
DI1
DI2
A
nalog –
D
igital Input
N
etwork
GND Tx/Rx
EVD
evolution
E
X
V connection
B
R
elay
B
NO B
COM B
4
2
3
1
aa
twin
b
Fig. 2.b
Terminal
Description
G,G0
Power supply
VBAT
Emergency power supply
Functional earth
1,3,2,4: ExV
connection A
Stepper motor power supply driver A
COM A, NO A Alarm relay driver A
1,3,2,4: ExV
connection B
Stepper motor power supply driver B
COM B, NO B Alarm relay driver B
GND
Signal ground
VREF
Power supply to active probes
S1
Probe 1 (pressure) or 4 to 20mA external signal
S2
Probe 2 (temperature) or 0 to 10 V external signal
S3
Probe 3 (pressure) or 4 to 20mA external signal
S4
Probe 4 (temperature)
DI1
Digital input 1
DI2
Digital input 2
Terminal for tLAN, pLan, RS485/ModBus® connection
Terminal for tLAN, pLan, RS485/ModBus® connection
Terminal for pLan, RS485/ModBus® connection
aa
service serial port (remove the cover for access)
b
serial port
Tab. 2.a
2.3 Connection diagram - superheat control
G
G0
G
G0
VBA
T
CO
M
A
NO
A
1 3 2 4
NET
Tx/Rx
GND
DI1
S4
S3
S2
S1
GND
DI2
VREF
2 AT
24 Vac
230 Vac
35 VA
shield
E
VD4
PC
EVD4 ser
vice USB adapt
er
EE
V driv
er
4
S
EVDCNV00E0
Analog - Digital Input
Network
OPEN A
CLOSE A
OPEN B
CLOSE B
A
B
C
OMB
NOB
1 3
2 4
A
shield
TRADRFE240
4
1
2
3
8 9 10
11
12
6
13
14
7
15
16
5
S
B
17
18
CAREL E
X
V
VALVE B
CAREL E
X
V
VALVE A
EV
D
evolution
twin
Fig. 2.c
Key:
1
green
2
yellow
3
brown
4
white
5
personal computer for configuration
6
USB/tLAN converter
7
ratiometric pressure transducer–evaporation pressure driver A
8
NTC – suction temperature driver A
9
ratiometric pressure transducer–evaporation pressure driver B
10
NTC – suction temperature driver B
11
digital input 1 configured to enable control driver A
12
digital input 2 configured to enable control driver B
13
voltage-free contact driver A (up to 230 V)
14
solenoid valve A
15
alarm signal A
16
voltage-free contact driver B (up to 230 V)
17
solenoid valve B
18
alarm signal B
Note:
•
connect the valve cable shield to the electrical panel earth;
•
the use of driver A for superheat control requires the use of the evaporation
pressure probe S1 and the suction temperature probe S2, which will be
fitted after the evaporator, and digital input 1 to enable control. As an
alternative to digital input 1, control can be enabled via remote signal
(tLAN, pLAN, RS485/ModBus®). For the positioning of the probes relating to
other applications, see the chapter on “Control”;
•
the use of driver B for superheat control requires the use of the evaporation
pressure probe S3 and the suction temperature probe S4, which will be
fitted after the evaporator, and digital input 2 to enable control. As an
alternative to digital input 2, control can be enabled via remote signal
(tLAN, pLAN, RS485/ModBus®). For the positioning of the probes relating to
other applications, see the chapter on “Control”;
•
inputs S1, S2, S3 & S4 are programmable and the connection to the
terminals depends on the setting of the parameters. See the chapters on
“Commissioning” and “Functions”;