Trailer Jockey Operators Handbook
41
If the driver does not respond to the regeneration indicator
light and perform a manual regeneration, the CHECK
ENGINE light will also be illuminated. If regeneration is still
not performed, after a period of time the STOP ENGINE light
will be illuminated. Move the vehicle to a safe location, stop
the engine and call for service.
If the DPF indicator light starts to flash, a manual regenera-
tion cycle must be performed, using the following procedure.
1. Drive the truck to a safe area and stop the truck.
2. Set parking brake and shift transmission to
N
(Neu-
tral).
3. Verify that no other indicator lights are illuminated (in
particular, the Check Engine light).
4. Depress the regeneration switch on the right side of the
cab control panel (). The engine speed will increase to
approximately 1600 RPM. Once the engine temperature
has been raised to an appropriate level, the regenera-
tion cycle will be started.
5. After approximately 20 to 40 minutes, the regeneration
cycle will be complete and the engine speed will drop to
idle (approximately 700 RPM).
Figure 4-2 Regeneration Switch
Do not go near the engine exhaust system during
regeneration, as temperatures can exceed 1,100 ºF (593 ºC).