CDE500 Vector Control AC Drive
Chapter 6 Parameters Description
-113-
Figure 6- 6 Stop DC brake
b1.17
Range: 0~3
Default: 0
Running mode
when running
frequency lower
than frequency
lower limit
The parameter determined drive action when setting frequency lower than
frequency lower limit.
0: Run at frequency lower limit
1: Run at zero speed
2: Stop
3: Stop,restart when setting frequency higher than lower limit.
b1.18
Range: 0~1
Default: 0
Keypad direction
You can change the rotation direction of the motor just by modifying this
parameter without changing the motor wiring. It is valid whatever the
command source is.
0: Same direction
1: Reverse direction