Specifications
Power Requirements
SmartLock
®
Controller: ............................................ 12 VDC, 100 mA
NOTE
:
When determining power supply current requirements, you must consider lock
and reader current draw if using the same supply for these devices.
NOTE
:
In some jurisdictions, the use of a UL approved power supply and connection
to the fire alarm system for emergency release may be required. Installers should
contact the local authority having jurisdiction to verify the specific requirements. Also,
a building permit may be required in some jurisdictions for the installation of
maglocks.
Communications Cable
(multi-drop configuration)
RS-485 Cable: ................... 22 AWG, Stranded/Shielded, Twisted Pair
.............................................................
609 m
(2000 ft)
max total length
.....................................................................
Belden 88761 or equivalent
On-Board Outputs
Lock Control: ................................... Form “C”, Rated @ 30 VDC, 1A
Door Operator: ................................. Form “C”, Rated @ 30 VDC, 1A
Forced/DHO Relays: ....................... Form “C”, Rated @ 30 VDC, 1A
On-Board Inputs
Exit Button: .................................................................... Normally Open
Door Contact: ............................................................... Normally Closed
Door Operator: ............................................................... Normally Open
...........................................................................................................................