SmartLock
®
Pro
Page 11 of 29
Installation Manual
April 2009 • Rev. 1.7
CANLAN NETWORK COMMUNICATIONS DEVICE
1
2
3
4
5
6
7
8
O
N
COMMS
LED
R
S
-4
8
5
SHIELD
B A GND
GND
+12 VDC
O
N
8
1
+
5
V
+
1
2
V
N/O
N/C
O
F
F
N/C
N/C
N/O
N/O
- Each Smartlock controller must
have a unique address
- For communication wiring, use 22
AWG, twisted pair, stranded,
shielded cable, 2000ft (
) MAX
total length.
609 m
- Canlan needs to be configured for
RS-485 communications. Refer to
the Canlan Installation and
Configuration guide for details.
NOTES:
ADDRESS “1” SHOWN
(Dipswitch 1 is OFF)
CANLAN
TCP\IP CONTROLLER
SMARTLOCK
CONTROLLER
#1
O
N
O
F
F
O
N
8
1
+
5
V
+
1
2
V
ADDRESS
SWITCH
B A GND
B A GND
SHIELD
GND
+12 VDC
SMARTLOCK
CONTROLLER
#2
TO OTHER
SMARTLOCK
CONTROLLERS
- 30 CONTROLLERS MAXIMUM
- 609 m (2000 ft.) MAXIMUM LENGTH