SmartLock
®
Pro
Page 13 of 29
Installation Manual
April 2009 • Rev. 1.7
PROGRAMMING MODULE (STAND-ALONE)
NOTES
:
The stand-alone programming module must be installed within 50 feet
of the SmartLock controller in a location accessible for programming
using the portable programming key.
The programming module should be installed on the secure side of the
door in a dry location.
If an iButton
®
reader is being used, wire it to the same reader port in
parallel with the programming module.
The programming module comes in a plastic box. Drill the required
holes for mounting and feed the cable through the cable feed-through.
See the
SmartLock Connect Operator Guide
for complete instructions on
programming using the portable programming key.
+
5
V
+
1
2
V
N/O
N/C
N/C
N/C
N/O
N/O
VCC
BEEP
RED LED
GREEN LED
TK
GND
1
2
3
4
5
6
7
8
ON
OFF
DIP SWITCH POSITIONS THROUGH
MUST BE
FOR STAND-ALONE OPERATION
1
6
ON
CABLE: 22 AWG, 6 CONDUCTOR,
STRANDED, 50 ft (15m) MAX LENGTH
GND
+12 VDC