MAPMINI
Page 8 of 28
Installation Manual
September 2021 • Rev. 1.4
Important Installation Notes
Controller Provisioning Options:
The MAPMINI controller is provisioned with the default 1-door configuration. The
MAPMINI can run only in one mode either
First Access
,
Webster
or
CloudACS
. The
MAPMINI can be provisioned in one of the two options below:
1.
Door controller Mode
1–door configuration: 1 lock relay, 1 multi-function relay, 1 REX/RTE, 1 door
contact/DPS (Door Position Switch).
2.
Input and Output controller Mode
2 general-purpose input points and 2 general-purpose output points available.
No door combination i.e. no lock relay and no multi-function relay.
Electrical Information:
1.
The MAPMINI utilizes a mini-computer and
must be operated using a battery
backed up power supply
to protect the hardware, system files and data files
from corruption due to power outage.
See Note 1 in Appendix section.
2.
CAUTION
: Do not unplug the MAPMINI Power connector if the system is in
operation as data corruption may occur on the MAPMINI mini-computer.
Please follow the instructions from the section “
Shutdown Button
”.
3.
Ensure that adequate 12V
DC power and 1A of current
is available, especially when
the same power supply is used
for the locks.
See suggested
power supplies in Appendix section
.
4.
It is highly recommended to use a separate power supply for locks as they
require a high amount of current for proper operation.
Figure 2