MAP1
Page 8 of 31
Installation Manual
June 2018 • Rev. 1.6
Important Installation Notes
Controller Provisioning Options:
The MAP1 controller is factory provisioned with default 2-door configuration running
in
First Access
mode (
First Access software is needed – database stored on computer
). The
Webster
mode (
Web based – database stored on panel and no software is needed
) and the
Cloud Lock
mode (
Cloud based – database stored on cloud server
) can be enabled with an
authorized provisioning file obtained from Cansec upon purchase. The MAP1 can run
only in one mode at a time and can also be provisioned in one of two options below.
1.
Door controller with or without auxiliary input and output points
a.
2–door configuration: 2 lock relays, 2 multi-function relays, 2 REX/RTE, 2
door contacts/DPS, 4 input points and 4 output points.
OR
b.
4–door configuration: 4 lock relays, 4 multi-function relays, 4 REX/RTE, 4
door contacts/DPS, 0 input points and 0 output points.
2.
Input and Output controller only. 8 input and 8 output points available. No
door combination i.e. no lock relay and no multi-function relay.
Electrical Information:
1.
The MAP1 utilizes a mini-computer and
must be operated using a battery
backed up power supply
to protect the hardware, system files and data files
from corruption due to power outage.
See Note 1 in Appendix section.
2.
CAUTION
: Do not unplug the MAP1 Power connector if the system is in
operation as data corruption may occur on the MAP1 mini-computer. Please
follow the instructions from the section “
PB1 -
Shut Down
”.
Figure 2
Содержание MAP1
Страница 1: ...MAP1 Controller INSTALLATION MANUAL June 2018...
Страница 7: ...MAP1 Page 7 of 31 Installation Manual June 2018 Rev 1 6 MAP1 Controller Layout Figure 1...
Страница 13: ...MAP1 Page 13 of 31 Installation Manual June 2018 Rev 1 6 Figure 6 Non Supervised...
Страница 14: ...MAP1 Page 14 of 31 Installation Manual June 2018 Rev 1 6 Figure 7 Supervised...
Страница 17: ...MAP1 Page 17 of 31 Installation Manual June 2018 Rev 1 6 INPUT AND OUTPUT POINT WIRING General Layout Figure 10...