3-2. Part Replacement Procedures
Be sure to protect the machine from static electricity in repair servicing, especially for the LCD, operation panel board, scanner
unit, logic board, card board, WLAN board, modular board, and PE sensor board.
Some of the photos below are for the MX860, since its structure is similar to that of the MX870.
(1) External housing, scanner unit, and document cover removal
MX870
--- 3. REPAIR
TABLE OF CONTENTS
1) Remove the cassette and the rear guide unit. (no screws)
2) Remove the AC adapter. (1 screw)
<Pull out the AC adapter from the bottom of the bottom case.>
<The core fits to the AC adapter rib.>
See "
4-5. Special Notes on Servicing, (7) Power supply unit and modular board replacement
."
3) Remove the side cover R. (2 screws)
<The scanner unit hinges are fitted in the right and left side covers.>
24 / 63
Содержание PIXMA MX870 Series
Страница 8: ...5 63 ...
Страница 9: ...6 63 ...
Страница 31: ...8 Remove the main case no screws 28 63 ...
Страница 34: ...31 63 ...
Страница 35: ...4 Remove the LCD ass y no screws 5 Remove the panel board 11 screws 32 63 ...
Страница 39: ...2 Remove the PE sensor board 5 screws 36 63 ...
Страница 64: ... 2 Service test print Service test print sample unified inspection pattern print 61 63 ...