##111
TX / RX Memory error
- Eliminate all the data, and
register them again.
##114
RX
RTN has been received.
- Increase the transmission level of
the sending machine.
##200
RX
A carrier has not been detected for 5 seconds during image
reception.
- Increase the transmission level of
the sending machine.
##201
TX / RX DCN has been received in a method other than the binary
procedure.
- Set the other machine ready for
reception.
##204
TX
DTC has been received even when there is no sending data.
##220
TX / RX System error (main program hang-up)
- Turn the machine off, and turn it
on again
- Modular board
- Logic board
##224
TX / RX An error has occurred in the procedure signal in G3
transmission.
##226
TX / RX The stack pointer has shifted from the RAM area.
- Turn the machine off, and turn it
on again.
##229
RX
The recording area has been locked for 1 minute.
- After the area is unlocked, print
the recorded image.
##232
TX
The encoder control unit has malfunctioned.
- Modular board
- Logic board
##237
RX
The decoder control unit has malfunctioned.
- Modular board
- Logic board
##238
RX
The print control unit has malfunctioned.
- Modular board
- Logic board
##261
TX / RX A system error has occurred between the modem and the system
control board.
- Modular board
- Logic board
##280
TX
Re-transmission of the procedure signal has been attempted the
specified number of times, but failed.
- Try a higher transmission level.
##281
TX
Re-transmission of the procedure signal has been attempted the
specified number of times, but failed.
- Try a higher transmission level.
##282
TX
Re-transmission of the procedure signal has been attempted the
specified number of times, but failed.
- Try a higher transmission level.
##283
TX
Re-transmission of the procedure signal has been attempted the
specified number of times, but failed.
- Try a higher transmission level.
##284
TX
After TCF transmission, DCN has been received.
- Set the receiving machine ready
for reception.
##285
TX
After EOP transmission, DCN has been received.
- Re-send the fax.
##286
TX
After EOM transmission, DCN has been received.
- Re-send the fax.
##287
TX
After MPS transmission, DCN has been received.
- Re-send the fax.
##288
TX
After EOP transmission, a signal other than PIN, PIP, MCF,
RTP, RTN has been received.
##289
TX
After EOM transmission, a signal other than PIN, PIP, MCF,
RTP, RTN has been received.
##290
TX
After MPS transmission, a signal other than PIN, PIP, MCF,
RTP, RTN has been received.
##670
TX
In V.8 late start, the DIS V.8 ability from the receiving machine
was detected, and CI was sent in response; however, the
procedure failed, causing T1 time-over.
- In bit 0 of the service data #1
SSSW SW28, prohibit the V.8 /
V.34 procedure of the sending
15 / 63
Содержание PIXMA MX870 Series
Страница 8: ...5 63 ...
Страница 9: ...6 63 ...
Страница 31: ...8 Remove the main case no screws 28 63 ...
Страница 34: ...31 63 ...
Страница 35: ...4 Remove the LCD ass y no screws 5 Remove the panel board 11 screws 32 63 ...
Страница 39: ...2 Remove the PE sensor board 5 screws 36 63 ...
Страница 64: ... 2 Service test print Service test print sample unified inspection pattern print 61 63 ...
Страница 65: ... 3 Ink absorber counter value print Print sample 4 6 Verification After Repair 62 63 ...