Service Mode > COPIER > FUNCTION > INSTALL
Service Mode > COPIER > FUNCTION > INSTALL
COPIER> FUNCTION> INSTALL
E-RDS
ON/OFF of Embedded-RDS
Details
To set ON/OFF of Embedded-RDS function.
Use case
When using Embedded-RDS
Adj/set/operate method "1) Enter the value, and then press OK key.
2) Turn OFF/ON the main power switch."
Caution
Be sure to use ERDS, RGW-PORT, COM-TEST, COM-RSLT, and
COM-LOG as a set.
Display/adj/set range
"0 to 1
0: OFF, 1: ON"
Default value
0
Related service mode COPIER> FUNCTION> INSTALL> RGW-PORT, COM-TEST, COM-
RSLT, COM-LOG
Supplement/memo
"Embedded-RDS: Function to send device information such as the
device counter, failure, and consumables to UGW via SOAP protocol
UGW (Universal Gate Way): Remote monitoring service system"
RGW-PORT
Set port number of Sales Co’s server
Details
To set the port number of the sales company’s server to be used for
Embedded-RDS.
Use case
When using Embedded-RDS
Adj/set/operate method 1) Enter the setting value, and then press Start key.
2) Turn OFF/ON the main power switch.
Caution
Be sure to use E-RDS, RGW-PORT, COM-TEST, COM-LOG and
RGW-ADR as a set.
Display/adj/set range
1 to 65535
Default value
443
Related service mode COPIER> FUNCTION> INSTALL> E-RDS, COM-TEST, COM-LOG,
RGW-ADR
COPIER> FUNCTION> CLEAR>ERDS-DAT
Supplement/memo
Embedded-RDS: Function to send device information such as the
device counter, failure, and consumables to the sales company’s server
via SOAP protocol
COM-TEST
Execution of Embedded-RDS communication test
Details
To execute Embedded-RDS communication test.
If the connection fails, the information is added to the communication
error log.
Use case
When using Embedded-RDS
Adj/set/operate method Select the item, and then press OK key.
Caution
Be sure to use ERDS, RGW-PORT, COM-TEST, COM-RSLT, and
COM-LOG as a set.
Default value
0
Related service mode COPIER> FUNCTION> INSTALL> ERDS, RGW-PORT, COM-RSLT,
COM-LOG
Supplement/memo
Embedded-RDS: Function to send device information such as the
device counter, failure, and consumables to UGW via SOAP protocol
UGW (Universal Gate Way): Remote monitoring service system
COPIER> FUNCTION> INSTALL
COM-RSLT
Embedded-RDS communication test result
Details
To display the Embedded-RDS communication test result.
Use case
When using Embedded-RDS
Adj/set/operate method N/A (Display only)
Caution
Be sure to use ERDS, RGW-PORT, COM-TEST, COM-RSLT, and
COM-LOG as a set.
Display/adj/set range
When not in execution: Unknown, When connection is completed: OK,
When connection is failed: NG
Default value
Unknown
Related service mode COPIER> FUNCTION> INSTALL> ERDS, RGW-PORT, COM-TEST,
COM-LOG
Supplement/memo
Embedded-RDS: Function to send device information such as the
device counter, failure, and consumables to UGW via SOAP protocol
UGW (Universal Gate Way): Remote monitoring service system
COM-LOG
Embedded-RDS communication error log
Details
To display the Embedded-RDS communication error log.
The dates, times, and error codes of the latest 5 errors that occurred
are displayed.
As for the error detail information, the report can be output by executing
COPIER> FUNCTION> MISC-P> ERDS-LOG.
Use case
When using Embedded-RDS
Adj/set/operate method Select the item, and then press OK key.
Caution
Be sure to use ERDS, RGW-PORT, COM-TEST, COM-RSLT, and
COM-LOG as a set.
Display/adj/set range
No.: 2 digits, Date: 8 digits, Time: 4 digits, Error code: 8 digits
Related service mode "COPIER> FUNCTION> INSTALL> ERDS, RGW-PORT, COM-TEST,
COM-RSLT
COPIER> FUNCTION> MISC-P> ERDS-LOG"
Supplement/memo
Embedded-RDS: Function to send device information such as the
device counter, failure, and consumables to UGW via SOAP protocol
UGW (Universal Gate Way): Remote monitoring service system
AINR-OFF
ON/OFF warm-up rotn deact:dor open/close
Details
To set whether to disable the warm-up rotation when opening and
closing the door.
By selecting 1, printing can be executed without auto adjustment at
warm-up rotation when analyzing the cause of a problem.
Use case
When printing and checking without auto adjustment at warm-up
rotation when analyzing the cause of a problem
Adj/set/operate method 1) Enter the setting value, and then press Start key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
0 to 1
0: OFF (warm-up rotation enabled), 1: ON (warm-up rotation disabled)
Default value
0
T-8-35
Содержание imageRUNNER C1325 Series
Страница 14: ...1 1 Product Overview Product Overview Product Lineup Features Specifications Parts Name ...
Страница 372: ...7 7 Error Jam Alarm Error Jam Alarm Overview Error Code Jam Code Alarm Code ...
Страница 429: ...7 7 7 58 7 58 Error Jam Alarm Jam Code Jam Type Error Jam Alarm Jam Code Jam Type PS101 PS103 PS102 PS101 F 7 3 F 7 4 ...
Страница 440: ...8 8 Service Mode Service Mode Overview COPIER FEEDER FAX TESTMODE ...
Страница 600: ... Service Tools General Circuit Diagram Backup Data Soft counter specifications Appendix ...
Страница 602: ...10 3 10 3 Appendix Service Tools Special Tools Appendix Service Tools Special Tools Solvents and Oils None ...