2
2
2-108
2-108
Technical Explanation > Embedded RDS > Product Overview > Major Functions
Technical Explanation > Embedded RDS > Product Overview > Major Functions
Embedded RDS
Product Overview
■
Overview
Embedded RDS (hereinafter referred to as E-RDS) is a monitoring program that runs on the
host machine. When the monitoring option is enabled by making the setting on this machine,
information such as the status change of the machine, counter information, and failure
information are collected. The collected device information is sent to a remote maintenance
server called UGW (Universal Gateway Server) via Internet, thus allowing for e-Maintenance/
imageWARE Remote (Remote Diagnosis System).
The following device information/ status can be monitored.
• Billing counts
• Parts counter
• Firmware info
• Service call error log
• Jam log
• Alarm log
• Status changes (Toner low/ out, etc.)
Since high confidentiality is required for the information shown above, it performs
communication between this machine and the UGW using HTTPS/ SOAP protocol.
The e-Maintenance/ imageWARE Remote system configuration
UGW
Internet
Firewall
DNS Server
This machine
Proxy Server
Administrator
Customer
Environment
Sales Company
F-2-144
■
Features and benefits
E-RDS embedded with a network module in advance can realize a front-end processing
of e-Maintenance/ imageWARE Remote system without attaching any extra hardware
equipment.
■
Major Functions
●
Service mode menu Transmission
E-RDS sends the target service mode menu data to UGW in the following cases:
• When a specific alarm and service call error are detected
• When the setting is changed in service mode
The following shows the transmission timing and the target data for transmission in service
mode menu:
Transmission timing
Transmitting data
Error retry
When the following alarm is detected.
Alarm codes for transmission:
0x060002, // Fixing
0x060004 - 0x069999, // Fixing
0x090005 - 0x099999, // Dram
0x100006 - 0016, 0x100022 - 0099,
0x100101 - 9900, // Development
0x300001 - 0x309999 // High voltage
COPIER
Display
ANALOG
No
HV-STS
CCD
DPOT
DENS
FIXING
SENSOR
MISC
HT-C
HV-TR
P-PASCAL
When the following service call error is detected.
Error codes for transmission:
E000 - E00F, // Fixing
E020, // Development ATR
E060 - E06F // High voltage
COPIER
Display
ANALOG
No
HV-STS
CCD
DPOT
DENS
FIXING
SENSOR
MISC
HT-C
HV-TR
P-PASCAL
When a value is set to [COPIER - Adjust]
subordinate’s Service mode menu.
(Transmission will be done at 60 min, later of
setting)
COPIER
Adjust
Yes
Содержание imageRUNNER C1325 Series
Страница 14: ...1 1 Product Overview Product Overview Product Lineup Features Specifications Parts Name ...
Страница 372: ...7 7 Error Jam Alarm Error Jam Alarm Overview Error Code Jam Code Alarm Code ...
Страница 429: ...7 7 7 58 7 58 Error Jam Alarm Jam Code Jam Type Error Jam Alarm Jam Code Jam Type PS101 PS103 PS102 PS101 F 7 3 F 7 4 ...
Страница 440: ...8 8 Service Mode Service Mode Overview COPIER FEEDER FAX TESTMODE ...
Страница 600: ... Service Tools General Circuit Diagram Backup Data Soft counter specifications Appendix ...
Страница 602: ...10 3 10 3 Appendix Service Tools Special Tools Appendix Service Tools Special Tools Solvents and Oils None ...