E021 0120 Title
Developing Screw rotation detection error (Y)
Description The difference between the maximum and the minimum of sampling values
detected by the ATR Sensor (Y) in the Drum Unit (Y) was 0.5 V or less.
Remedy
[Related parts]
• Drum Unit (Y) (Unit of replacement: DEVE_UNIT_Y)
• Harness between the Drum Unit Relay PCB (Y) (UN08/J6001) and
the DC Controller PCB (UN04/J160) (Unit of replacement: PROCESS
CONTROL PCB ASS’Y)
• Drum Unit Relay PCB (Y) (UN08) (Unit of replacement: PROCESS
CONTROL PCB ASS’Y)
• Drum Unit Memory PCB (Y) (UN12) (Unit of replacement: DEVE_UNIT_Y)
• DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB
ASSEMBLY)
• Main Drive Unit (Unit of replacement: MAIN DRIVE ASSEMBLY)
[Points to note at work]
• When checking the harness/cable or connector, perform the following
work.
1. Disconnect and then connect the connector to check that there is no bent
pin and cable disconnection.
2. Visually check that the harness is not caught or open circuit.
3. If there is any error, replace the corresponding harness/cable.
• If the Drum Unit Memory PCB (Y) is soiled, clean it with a blower.
[Remedy] Check/replace the related parts.
E021 0220 Title
Developing Screw rotation detection error (M)
Description The difference between the maximum and the minimum of sampling values
detected by the ATR Sensor (M) in the Drum Unit (M) was 0.5 V or less.
Remedy
[Related parts]
• Drum Unit (M) (Unit of replacement: DEVE_UNIT_M)
• Harness between the Drum Unit Relay PCB (M) (UN09/J6002) and
the DC Controller PCB (UN04/J160) (Unit of replacement: PROCESS
CONTROL PCB ASS’Y)
• Drum Unit Relay PCB (M) (UN09) (Unit of replacement: PROCESS
CONTROL PCB ASS’Y)
• Drum Unit Memory PCB (M) (UN13) (Unit of replacement: DEVE_UNIT_
M)
• DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB
ASSEMBLY)
• Main Drive Unit (Unit of replacement: MAIN DRIVE ASSEMBLY)
[Points to note at work]
• When checking the harness/cable or connector, perform the following
work.
1. Disconnect and then connect the connector to check that there is
no bent pin and cable disconnection.
2. Visually check that the harness is not caught or open circuit.
3. If there is any error, replace the corresponding harness/cable.
• If the Drum Unit Memory PCB (M) is soiled, clean it with a blower.
[Remedy] Check/replace the related parts.
Error
code
Detail
Code
Item
Description
E021 0320 Title
Developing Screw rotation detection error (C)
Description The difference between the maximum and the minimum of sampling values
detected by the ATR Sensor (C) in the Drum Unit (C) was 0.5 V or less.
Remedy
[Related parts]
• Drum Unit (C) (Unit of replacement: DEVE_UNIT_C)
• Harness between the Drum Unit Relay PCB (C) (UN10/J6003) and
the DC Controller PCB (UN04/J162) (Unit of replacement: PROCESS
CONTROL PCB ASS’Y)
• Drum Unit Relay PCB (C) (UN10) (Unit of replacement: PROCESS
CONTROL PCB ASS’Y)
• Drum Unit Memory PCB (C) (UN14) (Unit of replacement: DEVE_UNIT_C)
• DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB
ASSEMBLY)
• Main Drive Unit (Unit of replacement: MAIN DRIVE ASSEMBLY)
[Points to note at work]
• When checking the harness/cable or connector, perform the following
work.
1. Disconnect and then connect the connector to check that there is
no bent pin and cable disconnection.
2. Visually check that the harness is not caught or open circuit.
3. If there is any error, replace the corresponding harness/cable.
• If the Drum Unit Memory PCB (C) is soiled, clean it with a blower.
[Remedy] Check/replace the related parts.
E021 0420 Title
Developing Screw rotation detection error (Bk)
Description The difference between the maximum and the minimum of sampling values
detected by the ATR Sensor (Bk) in the Drum Unit (Bk) was 0.5 V or less.
Remedy
[Related parts]
• Drum Unit (Bk) (Unit of replacement: P-UNIT_BK)
• Harness between the Drum Unit Relay PCB (Bk) (UN11/J6004) and
the DC Controller PCB (UN04/J162) (Unit of replacement: PROCESS
CONTROL PCB ASS’Y)
• Drum Unit Relay PCB (Bk) (UN11) (Unit of replacement: PROCESS
CONTROL PCB ASS’Y)
• Drum Unit Memory PCB (Bk) (UN15) (Unit of replacement: P-UNIT_BK)
• DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB
ASSEMBLY)
• Main Drive Unit (Unit of replacement: MAIN DRIVE ASSEMBLY)
[Points to note at work]
• When checking the harness/cable or connector, perform the following
work.
1. Disconnect and then connect the connector to check that there is no bent
pin and cable disconnection.
2. Visually check that the harness is not caught or open circuit.
3. If there is any error, replace the corresponding harness/cable.
• If the Drum Unit Memory PCB (Bk) is soiled, clean it with a blower.
[Remedy] Check/replace the related parts.
Содержание imageRUNNER C1325 Series
Страница 14: ...1 1 Product Overview Product Overview Product Lineup Features Specifications Parts Name ...
Страница 372: ...7 7 Error Jam Alarm Error Jam Alarm Overview Error Code Jam Code Alarm Code ...
Страница 429: ...7 7 7 58 7 58 Error Jam Alarm Jam Code Jam Type Error Jam Alarm Jam Code Jam Type PS101 PS103 PS102 PS101 F 7 3 F 7 4 ...
Страница 440: ...8 8 Service Mode Service Mode Overview COPIER FEEDER FAX TESTMODE ...
Страница 600: ... Service Tools General Circuit Diagram Backup Data Soft counter specifications Appendix ...
Страница 602: ...10 3 10 3 Appendix Service Tools Special Tools Appendix Service Tools Special Tools Solvents and Oils None ...