Service Mode > FAX > List of NCU > CNGDTCT
Service Mode > FAX > List of NCU > CNGDTCT
2) Numeric value parameter
Parameter No.
Function
Setting range
001
002
T1 timer
0 to 9999 (x10ms)
003
T2 timer
0 to 9999 (x10ms)
004
T3 timer
0 to 9999 (x10ms)
005
T4 timer
0 to 9999 (x10ms)
006
Signal detection table
0 to 16
007
Signal detection level
0 to 7
008
Number of valid tone detection 0 to 9999 (times)
■
REORDRTN
1) Bit switch
Bit No.
Function
1
0
Bit 0
Bit 1
Signal detection
method
FED
FR3
Bit 2
Signal frequency
Changed
Not changed
Bit 3
Bit 4
Judgment of intermittent
signal
Start from valid ON
signal
Start from either valid
ON signal or OFF signal
Bit 5
Bit 6
Signal form
Continuous
Intermittent
Bit 7
Signal detection
Detected
Not detected
2) Numeric value parameter
Parameter No.
Function
Setting range
001
002
T1 timer
0 to 9999 (x10ms)
003
T2 timer
0 to 9999 (x10ms)
004
T3 timer
0 to 9999 (x10ms)
005
T4 timer
0 to 9999 (x10ms)
006
Signal detection table
0 to 16
007
Signal detection level
0 to 7
008
Number of valid tone detection 0 to 9999 (times)
T-8-37
T-8-38
T-8-39
■
MULTI
1) Numeric value parameter
Parameter No.
Function
Setting range
001
0 to 9999
002
0 to 9999
003
0 to 9999
004
0 to 9999
■
AUTO RX
1) Numeric value parameter
Parameter No.
Function
Setting range
001
CI ON time
0 to 9999 (x10ms)
002
Cl long off time
0 to 9999 (x10ms)
003
Cl off time
0 to 9999 (x10ms)
004
CL long off time
0 to 9999 (x10ms)
005
Cl MAX off time
0 to 9999 (x10ms)
006
Cl wait time
0 to 9999 (x10ms)
007
CI frequency
0 to 9999 (cycle)
008
CI frequency lower limit
0 to 9999 (Hz)
009
CI frequency upper limit
0 to 9999 (Hz)
■
CNGDTCT
1) Numeric value parameter
Parameter No.
Function
Setting range
001
At F/T switching CNG MIN ON time
0 to 9999 (x10ms)
002
CNG MAX ON time
0 to 9999 (x10ms)
003
004
005
006
Hit ratio
0 to 9999 (%)
007
At direct
connecting to
answering phone
CNG MIN ON time
0 to 9999 (x10ms)
008
CNG MAX ON time
0 to 9999 (x10ms)
009
Tolerable time of
instantaneous interruption
0 to 9999 (x10ms)
010
011
Number of detection
0 to 9999 (Times)
012
Hit ratio
0 to 9999 (%)
T-8-40
T-8-41
T-8-42
Содержание i-SENSYS MF229dw
Страница 11: ...1 1 Product Overview Product Overview Product Lineups Features Product Specifications Name of Parts ...
Страница 60: ...3 3 Periodical Services Periodical Services Periodically Replaced Parts Consumables Periodical Service ...
Страница 255: ...5 5 Adjustment Adjustment Mechanical Adjustment ...
Страница 257: ...6 6 Trouble Shooting Trouble Shooting Test Print Trouble Shooting Items Log Collector Version Upgrade ...
Страница 270: ...7 7 Error Codes Error Codes Overview Error Codes Jam Codes ...
Страница 274: ...8 8 Service Mode Service Mode Overview COPIER FEEDER FAX TESTMODE NETWORK ...