4
4
4-183
4-183
Disassembly/Assembly > Pickup Feed System (Simplex Model) > Removing the Pickup Unit (Simplex Model) > Procedure
Disassembly/Assembly > Pickup Feed System (Simplex Model) > Removing the Pickup Unit (Simplex Model) > Procedure
8) Turn the machine so that it is placed with its front side down.
9) Remove the 6 screws (TP) [1] and the screw (with toothed lock washer) [2].
7x
[2]
[1]
[1]
F-4-540
F-4-541
10) Remove the Pickup Unit [2] while opening the Pickup Tray [1].
[1]
[2]
CAUTION:
• When installing the Pickup Unit [1], be sure that the Contact Spring [2] is in contact
with the [A] part.
• Be sure to make the contact point [3] of the grounding come in contact with the [B]
part.
• Be sure to install the Pickup Unit [1] while holding the Pickup Tray [4].
(This is because the tension of the spring is applied to the Pickup Tray.)
[1]
[2]
[3]
[4]
[A]
[B]
F-4-543
F-4-542