4
4
4-125
4-125
Disassembly/Assembly > Fixing System (Duplex Model) > Removing the Fixing Assembly (Duplex Model) > Procedure
Disassembly/Assembly > Fixing System (Duplex Model) > Removing the Fixing Assembly (Duplex Model) > Procedure
8) Free the harness [1] from the Harness Guide [A].
9) Free the Fixing Harness [2] from the Harness Holder [3].
1x
1x
[1]
[A]
[3]
[2]
10) Remove the Harness Holder [1].
• 1 Claw [2]
[1]
1x
[2]
F-4-355
F-4-356
11) Remove the Rear Reinforcing Plate [1].
• 2 Screws (black TP) [2]
2x
[1]
[2]
[2]
12) Remove the Shaft Support [1] of the Delivery Roller.
[1]
[1]
F-4-357
F-4-358