4
4
4-49
4-49
Disassembly/Assembly > Original Exposure/Feed System (DADF Model) > Removing the Flat Bed Motor Unit (DADF Model) > Procedure
Disassembly/Assembly > Original Exposure/Feed System (DADF Model) > Removing the Flat Bed Motor Unit (DADF Model) > Procedure
2) Press the gear [1] to bend the belt [2], and remove the belt [2] from the gear [3].
CAUTION:
Grease is applied on the shaft [4] of the Contact Image Sensor, so be careful not to let
the belt [2] come in contact with the shaft.
[2]
[4]
F-4-108
[2]
[1]
[3]
F-4-109
3) Remove the Guide Cover [1].
• 1 Claw [2]
[2]
[1]
1x
4) Free the harness [1] and the Grounding Wire [2] from the hole [A] of the Reader Unit and
the Harness Guide [B].
[2]
[1]
[B]
1x
[A]
F-4-110
F-4-111
Содержание i-SENSYS MF229dw
Страница 11: ...1 1 Product Overview Product Overview Product Lineups Features Product Specifications Name of Parts ...
Страница 60: ...3 3 Periodical Services Periodical Services Periodically Replaced Parts Consumables Periodical Service ...
Страница 255: ...5 5 Adjustment Adjustment Mechanical Adjustment ...
Страница 257: ...6 6 Trouble Shooting Trouble Shooting Test Print Trouble Shooting Items Log Collector Version Upgrade ...
Страница 270: ...7 7 Error Codes Error Codes Overview Error Codes Jam Codes ...
Страница 274: ...8 8 Service Mode Service Mode Overview COPIER FEEDER FAX TESTMODE NETWORK ...