8
8
8-11
8-11
Service Mode > FEEDER > FUNCTION
Service Mode > FEEDER > FUNCTION
FEEDER
ADJUST
FEEDER > ADJUST
Sub item
Description
ADF
model
Other
DOCST
Adjustment of the page front reading position when
using ADF(common in SADF model and DADF model).
Setting range: -30 ~ 30
Yes
No
LA-SPD
Adjustment of magnification ratio in vertical scanning
direction in stream feeding.
0.1% precision
Setting range: -30 ~ 30
Yes
No
FUNCTION
FEEDER > FUNCTION
Sub item
Description
SADF
model
DADF
model
Other
FEED-CHK Paper feeding test for only ADF
Setting value
1: SADF
2:DADF
Yes
Yes
No
SL-ON
Operation start-up for solenoid
The solenoid is operated only for 100 ms because the
solenoid will burn if it is kept ON for a long period of time.
No
Yes
No
MTR-ON
Operation start-up for motor
Yes
Yes
No
FEED-ON
Paper feeding test for only ADF
Yes
Yes
No