2
2
2-69
2-69
Technical Reference > MEAP > Maintenance > Actions to be taken when E616 is displayed.
Technical Reference > MEAP > Maintenance > Actions to be taken when E616 is displayed.
●
Procedure for reinstalling MEAP applications after replacing the PCB
The following shows the procedure when replacing the PCB.
1
)
交換作業前準備
基板交換作業の前に、 以下の作業を行う。
• MEAP
アプリケーションによっては、 使用するデータをバックアップ、 またはエクスポートする機
能がある。 このような
MEAP
アプリケーションがインストールされている場合は、 データのバック
アップ、 またはエクスポートを行っておく。
• 再インストールするために、 すべての
MEAP
アプリケーションのライセンス
(
特殊ライセンスまた
は再利用可能ライセンスなど
)
をサービス作業用ノート
PC
にコピーしておく。
2) Replacing the drive
Prepare the necessary service parts, and replace the drive.
3) Reinstalling the MEAP application
When the device has started normally, obtain the jar files of the MEAP applications from the
user, and install them using the license files for reinstallation.
Installation method is the same as normal installation.
4) Importing user information
As necessary, make login service selections and import user information.
Note:
When you replace the PCB without uninstalling MEAP applications, make sure to
reinstall the previously installed applications. Unless reinstalling them, MEAP counter
will not be released and the message “The number of applications that can be installed
has exceeded the limit. Try to install this application after uninstalling other applications.”
is displayed so that the installation of new applications may not be accepted. If you
want to install new applications in this case, once reinstall the applications in-stalled
before formatting and uninstall unnecessary applications.
Note:
If a PCB which had been used in a device with a different serial number is installed in
another device, the MEAP area in the storage drive will be completely initialized.
■
Actions to be taken when E616 is displayed.
●
Overview
When E602 is displayed and then the device is restarted as a remedy, E616 may be
displayed in some cases.
This is a symptom that occurs when the power is cut off without shutdown (such as
disconnecting the plug of the device). The error code is displayed when the file system of the
MEAP storage area is in an abnormal status.
When the device is started, it checks the file system. If the device detects an error, it displays
the error code E602, disables the MEAP function, and then starts.
When the device is restarted according to the remedy for E602, the file system is recovered
automatically in the system. If the recovery procedure succeeds, the device starts normally
with the MEAP function enabled.
However, if the file system could not be recovered by auto recovery, E616 is displayed.
Since the system is automatically formatted when E616 is displayed, the installed MEAP
applications will disappear and the device's MEAP function itself will also be disabled.
For this reason, it is necessary to enable the MEAP function and then reinstall the MEAP
applications.
●
Work procedure
Perform the following procedure when E616 is displayed.
1) Start the device in service mode.
2) Select [ Setup ] > [ SERVICE MODE ] > [ FUNCTION GR. ] > [ MEAP FUNCTION ] > On to
enable the MEAP function.
3) Restart the device to start the MEAP function.
4) Access SMS, and then use a reusable license or special license for reinstallation to install
the MEAP application.
Note:
As for MEAP applications that were installed using reusable licenses, the reusable
licenses can be used to reinstall the applications. For other MEAP applications without
reusable licenses, use special license files to reinstall them, in the same as way as
handling a storage drive failure.
For information on how to obtain a special license for reinstallation, see "Special license
for reinstallation" in this chapter. Then contact the support department of the sales
company to have the license issued before starting the work.
5) Start the MEAP application.
Содержание Color imageRUNNER LBP5280
Страница 4: ...Blank Page ...
Страница 216: ...5 5 5 19 5 19 Troubleshooting Error Code Jam Code Troubleshooting Error Code Jam Code ...
Страница 276: ... General Timing Chart General Circuit Diagram Signal Input Output List Appendix ...
Страница 283: ...6 8 6 8 Appendix Backup Data Appendix Backup Data ...
Страница 284: ...6 9 6 9 Appendix Backup Data Appendix Backup Data ...