6-7
6-7
Appendix > Backup Data
Appendix > Backup Data
Backup Data
Data to Be Stored
Data
Location
Replacement
Delete
User Backup
Service Backup
User function
Service function
When
Replacing
Main PCB
DC
Controller
PCB
Initializing
the [Setup]
Menu(Settings)
Initializing
the Network
Settings(Settings)
IPSec
Policy
settings
delete*1
SD Card
Data All
Erase
Function
(Fixing unit/
ITB unit)
Initializing
the Service
counter
NVRAM
initialization
Initializing the
[Setup] Menu
DC Controller
PCB NVRAM
Clear
E-RDS >
CLEAR
CA-
KEY
Can Data
Be Backed
up?
Method
Location to
Be Stored
Can
Data Be
Backed
up?
Method 1
Location to
Be Stored
Method 2 Location to
Be Stored
Control Panel set value
(Except in network and
IPSec Policy Settings*1)
Main
Controller
PCB
Clear
-
Clear
-
-
-
Clear
-
-
-
Yes
Setup > User Maintenance
> IMPORT/EXPORT >
EXPORT
USB
memory
Yes
FUNCTION GR. > ECONF
> EXPORT
ALL(GENERAL/DEPEND/
SECURITY)
USB memory
-
Sublog
Expansion
Board
Sublog
Board
Control Panel set
value(Network)
Clear
-
-
Clear
-
-
-
-
-
-
Control Panel set
value(IPSec Policy
Settings) *1
Clear
-
-
-
Clear
-
-
-
-
-
No
-
-
No
-
-
-
-
SSL Keys
Clear
-
-
-
-
-
-
-
-
Clear
*5
No
-
-
No
-
-
-
-
CA Certificates
Clear
-
-
-
-
-
-
-
-
Clear
*5
No
-
-
No
-
-
-
-
MEAP(Application/
Settings/Data)
Clear
-
-
-
-
-
-
-
-
-
No
-
-
No
-
-
-
-
e-RDS
Clear
-
-
-
-
-
-
-
Clear
-
Yes
*4
Setup > User Maintenance
> IMPORT/EXPORT >
EXPORT
USB
memory
Yes
FUNCTION GR. > ECONF
> EXPORT
ALL(GENERAL/DEPEND/
SECURITY)
USB memory Sublog
Expansion
Board
Sublog
Board
Service DATA(Main
Controller PCB)
Clear
-
-
-
-
-
-
-
Clear
*3
-
DC Controller PCB NVRAM
Backup(Main Controller
PCB)
Clear
-
-
-
-
-
-
Clear
-
-
No
-
-
No
*6
-
Service DATA(DC
Controller PCB)
DC
Controller
PCB
-
Clear
-
-
-
-
-
-
-
-
No
-
-
Yes
*6
Main
Controller
PCB
-
-
Main Controller service
counter *2
Main
Controller
PCB
Stored Job
SD Card -
-
-
-
-
Clear
-
-
-
-
No
-
-
No
-
-
-
-
*1. To delete IPSec Policy settings, select the following in service mode: Network.gr >IPSEC SETTING > SPDALDEL.
*2. It belongs to counter gr. in service mode. Since counter gr. items are not available with this model, it is not applicable.
*3. It is initialized by selecting the following in service mode: Network gr. > E-RDS > CLEAR.
*4. Service mode setting values are stored in NVRAM. When importing/exporting user settings, the service mode items are included.
*5. It is initialized by selecting the following in service mode: Network gr. > CA-KEY.
*6. If setting information of the DC Controller PCB does not exist on the Main Controller PCB, automatic backup is performed.
If DC Controller PCB setting value already exists when installing the Main Controller PCB, automatic backup is not performed.
In service mode, clear DC Controller PCB NVRAM. Automatic backup is performed at next startup. FUNCTION GR. > CLEAR DCON (initialization of the backup area of the DC Controller PCB NVRAM)
When replacing the DC Controller PCB, restore backup information by selecting the following: FUNCTION GR. > RESTOR DCON.
T-6-2
Содержание Color imageRUNNER LBP5280
Страница 4: ...Blank Page ...
Страница 216: ...5 5 5 19 5 19 Troubleshooting Error Code Jam Code Troubleshooting Error Code Jam Code ...
Страница 276: ... General Timing Chart General Circuit Diagram Signal Input Output List Appendix ...
Страница 283: ...6 8 6 8 Appendix Backup Data Appendix Backup Data ...
Страница 284: ...6 9 6 9 Appendix Backup Data Appendix Backup Data ...