Chapter 3
3-2
T-3-1
Code
Cause
Description
E000
"xx" represents the heater.
xx=01: upper heater xx=02: lower heater xx=03: external heater
0001
The oil heater thermistor or the oil
thermistor or the external heating thermistor
has a short circuit.
The AC driver PCB is faulty.
The DC controller PCB is faulty.
The output of the oil heater thermistor does not reach 50
deg C within 2min after the oil heater has gone ON; as
detedted by the lowtemperature detection circuit on the
DC controller PCB (after the oil temperature has reached
a specific level).
When the high temperature detection circuit on the DC
controller PCB detects abnormal high temperature; then,
the power OFF signal (PWOFF*) is set to '0', and the
power switch (SW2) is turned OFF after that.
xx01
Fixing thermistor (short circuit)
External heat thermistor (short circuit)
Triac (short circuit)
The overheating detection circuit on the DC controller
PCB has detected an overheating condition.
A difference of 60 deg C or higher is detected between
the reading of the main thermistor and that of the sub
thermistor.
xx02
DC controller PCB (faulty)
The main thermistor has detected overheating (210 deg
C).
xx20
Fixing thermistor (poor contact, open
circuit)
Fixing heater (open circuit)
Triac (faulty)
DC controller PCB (faulty)
When control is to 160 deg C or less, a rise in temperature
of 10 deg C or more does not occur within 4 min.
xx40
The temperature drops to 140 deg C or less during
temperature control for standby.
xx50
The temperature drops to 140 deg C or less during
temperature control for printing.
0061
The oil heater thermistor or the oil
thermistor has a short circuit.
The AC driver PCB is faulty.
The DC controller PCB is faulty.
The oil thermistor has detected overheating (180 deg C).
0071
The oil thermistor has detected overheating (220 deg C).
0081
The hightemperature detection circuit on the DC
controller PCB has detected overheating (190 deg C for
the oil thermistor output; 230 deg C for the oil heater
thermistor).
0062
The oil heater thermistor or the oil
thermistor has an open circuit.
The AC driver PCB is faulty.
The DC controller PCB is faulty.
At the end of the WAIT period, the output of the oil
thermistor does not reach 50 deg C.
0072
At the end of the WAIT period, the oil heater thermistor
does not reach 50 deg C.
Содержание CLC5100 Series
Страница 1: ...Jul 7 2004 Portable Manual CLC5100 Series ...
Страница 2: ......
Страница 6: ......
Страница 11: ...Chapter 1 Maintenance and Inspection ...
Страница 12: ......
Страница 14: ......
Страница 49: ...Chapter 2 Standards and Adjustments ...
Страница 50: ......
Страница 77: ...Chapter 2 2 25 F 2 48 5 Tighten the screw 2 for the guide plate View 3 A 2 1 View ...
Страница 95: ...Chapter 3 Error Code ...
Страница 96: ......
Страница 97: ...Contents Contents 3 1 Error Code Details 3 1 3 1 1 Error Code Details 3 1 ...
Страница 98: ......
Страница 121: ...Chapter 4 User Mode Items ...
Страница 122: ......
Страница 123: ...Contents Contents 4 1 List of User Modes 4 1 ...
Страница 124: ......
Страница 127: ...Chapter 5 Service Mode ...
Страница 128: ......
Страница 130: ......
Страница 223: ...Chapter 6 Outline of Components ...
Страница 224: ......
Страница 226: ......
Страница 264: ...Chapter 6 ޓ 6 38 ...
Страница 265: ...Chapter 7 System Construction ...
Страница 266: ......
Страница 268: ......
Страница 282: ...Chapter 7 ޓ 7 14 ...
Страница 283: ...Chapter 8 Upgrading ...
Страница 284: ......
Страница 285: ...Contents Contents 8 1 Outline of the Version Upgrade 8 1 ...
Страница 286: ......
Страница 288: ......
Страница 289: ...Jul 7 2004 ...
Страница 290: ......