COPYRIGHT © 1999 CANON INC. CANON CLC1120/1130/1150 REV.0 MAR. 1999 PRINTED IN JAPAN (IMPRIME AU JAPON)
3-9
CHAPTER 3 EXPOSURE SYSTEM
A. Original Exposure System
1. Removing the Scanning Lamp
1) Remove the vertical side plate.
2) Remove the copyboard glass.
3) Remove the standard white plate cover.
4) Remove the screw [1], and detach the
right stay [2].
5) Remove the three screws [3], and detach
the anti-reflection plate [4].
Figure 3-401
Figure 3-402
Figure 3-403
[1]
[2]
[1]
[3]
[3]
[3]
[4]
[5]
[6]
6) Shift the scanning lamp to where the right
stay [2] was found. Turning a flat-blade
screwdriver in the direction of the arrow
[5], open the electrode plate in the
direction of the arrow [6] to detach the
scanning lamp.
Caution:
1. Do not work if the surface of the
scanning lamp is hot.
2. Do not leave fingerprints on the
surface of the scanning lamp.
3. Dry wipe the surface of the scanning
lamp if it is soiled.
2. Orienting the Scanning Lamp
Fit the scanning lamp so that the
protrusion [1] at its center is in the direction of
the arrow, and its side with a logo marking is
toward the rear.
Caution:
Do not touch the surface of the scanning
lamp when mounting it.
[1]
Содержание CLC 1120
Страница 6: ......
Страница 20: ......
Страница 22: ......
Страница 48: ......
Страница 94: ......
Страница 96: ......
Страница 114: ......
Страница 134: ......
Страница 136: ......
Страница 152: ......
Страница 242: ......
Страница 346: ......
Страница 374: ......
Страница 376: ......
Страница 412: ......
Страница 452: ......
Страница 454: ......
Страница 517: ......
Страница 531: ...13 4 COPYRIGHT 1999 CANON INC CANON CLC1120 1130 1150 REV 0 MAR 1999 PRINTED IN JAPAN IMPRIME AU JAPON ...
Страница 881: ......
Страница 893: ......
Страница 895: ......
Страница 899: ......
Страница 901: ...0499S1 5 1 PRINTED IN JAPAN IMPRIME AU JAPON This publication is printed on 70 reprocessed paper ...