Made in Germany
Camtec Power Supplies GmbH - Gewerbestraße 30 - DE-76327 Pfinztal / Germany
S.16/20 (07/2017.01.0)
Tel. +49 (721) 46596 - 0 Fax +49 (721) 46596 - 77
www.camtec-gmbh.com
-
(Technical changes and errors reserved. This product may not be used in life support systems.)
Electrical Safety (Factory-Test / Fieldtest Owner)
T
A
B
C
¹)
D
Type Test
60s 2500Vac 3000Vac 500Vdc
3000Vac
Factory Test
5s
2000Vac 2000Vac 500Vdc
1000Vdc
Field Test
2s
2000Vac 2000Vac 500Vdc
1000Vdc
¹)
≥
60Vdc= 1200Vdc /
≥
150Vdc= 2100Vdc
Type and Factorytest are the manufacturer. While repeating test, damage can
occur to the power supply unit. For the Fieldtest (owner) follow the below instruction:
a)
Use suitable test equipment, raising the voltage slowly
b)
Short circuit L1 and N, and all the DC output terminals.
c)
Use only test voltages of 50/60Hz. The outputs are unearthed and
therefore they have no resistance to GND/PE.
d)
If the residual voltage is
≥
60Vdc, observe the safety standards.
Use only specially insulated screwdriver to trim the Ua/Ia.