Features

 

 

Idling behavior

 

The CPS-EX Series is permanently open-circuit proof. When an output 
voltage is preset it comes stable. If a load is switched suddenly, the unit 
stabilized within <1ms. An overshoot of the output voltage is irrelevant. 
 

Start behavior

 

The power supply has a start delay of 1s to stabilize all measuring circuits 
for the interface messages accurately. The power supply starts with a 
ramp (soft start) of 100ms. The output voltage does not overshoot - 
regardless of whether a load is connected or not. 
 

Galvanic isolation and insulation

 

The switching power supply is galvanically isolated between the input and 
the output. All major digital inputs and outputs of the interface are 
electrically isolated. 
 

V programming (Ureg) 

The output voltage of the CPS-EX power supply can be adjusted by a 
control signal. The setting is linear to the input signal. The power supply 
operates data stable even at all output voltages. 

 

C programming (Ireg) 

The output current of the CPS-EX power supply can be adjusted by a 
control signal. The setting is linear to the input signal. The power supply 
operates data stable even at all output currents.

 

 

V Monitor (Umon) 

The power supply provides real-time monitoring of the output voltage. It is 
the exact and real value at the output terminals. If the sense line is used, 
the real value is measured directly at the load. The latency signal preset to 
the measured value is negligible, since the control circuit is constructed 
completely analogously.

 

 

C Monitor (Imon) 

The power supply provides real-time monitoring of the output current. It is 
the exact and real value at the output terminals. The latency signal preset 
to the measured value is negligible, since the control circuit is constructed 
completely analogously. 
 

Constant Voltage or Constant Current Mode (CV/CC)

 

The device can be operated as a DC voltage source or a constant current 
source. The operating mode is signaled on the interface.

 

 

Auxiliary Voltage (AUX)

 

The devices feature a 12V / 500mA auxiliary voltage to operate external 
peripheral. 
 

Potentiometer Internal Control (Uadj/Iadj) 

If the power supply shall only set with the built in internal potentiometers, 
the use of the internal reference voltage is possible. The power supply 
requires no external signals and can operate completely autonomously. 
 

Potentiometer External Control (Uadj/Iadj)

 

If the power supply shall only set with external potentiometers, the use of 
the internal reference voltage is possible. The power supply requires no 
external signals and can operate completely autonomously. 
 

Sense Mode 

The power supply has a sense mode to compensate for voltage drops of 
2V per load line. 
 

Fuse Mode

 

The unit can be operated in fuse mode. In the fuse mode, the unit is turned 
off and locked when it was more than 5 seconds in constant current mode 
to protect a connected defect load. The lock can be controlled remotely or 
repeal by disconnection from the mains again. 
 

Continuous Mode

 

The unit can be operated in continuous mode. In the continuous mode, the 
power supply provides constant current mode in a continuous flow and no 
ticker-operation. 

 

Master-Slave Mode (Ureg-Out/Ireg-OUT) 

The master-slave mode can be defined in the parallel operation. One device can 
be set as the master, the other involved network units act as a slave and the 
setting signals follow current / voltage, which are commanded by the Master. This 
ensures that all devices are operated synchronously. 
 

Current Share Bus (CS)

 

In parallel operation, the involved network components communicate with each 
other and share the total power evenly to each other. 
 

Remote Shutdown (SD) 

All CPS-EX devices have a remote shutdown (open collector or switching 
contacts). 
 

Inhibit Mode (Interlock) 

The inhibit circuit reliably prevents unintentional starting of the power supply. The 
control loop is internally locked. Since this blocking is done progressively it is 
active even when the control signal, is missing due to a cable break or temporarily 
suspends. A premature restart of the power supply is prevented. 
The inhibit input can be connected to a relay or switch. If the contact is interrupted, 
the power supply is switched off. If the contact is closed again, the power supply 
restarts.

 

 

DC and AC Fail 

By DC-fail the power supply reports that the power output is disabled. 
By AC-fail the power supply reports an AC undervoltage. Both signals have 
separate outputs. Each of them can be selected between NO and NC.

 

 

Over Voltage Protection (OVP) 

On the interface is a message signal. Until the abolition of the fault the device 
switches off. 
 

Over Current Protecttion (OCP)

 

On the interface is a message signal. Until the abolition of the fault the device 
switches off. 
 

Temperature Control (TEMP)

 

The operating temperature of the power supply can be monitored via a signal 
applied to the interface output. 

 

Temperature Alarm (TA)

 

If the device is in the critical range, a warning signal is applied to the interface. 
 

Over Temperature Thermal Shutdown (OT)

 

The device has a thermal monitoring: shutdown with automatic restart. The OT 
signal is applied to the interface.

 

 

Fan Failure Monitoring (FF)

 

If it comes to a fan failure or blocking, a signal is applied to the interface. The 
speed signal of the fan is monitored. Thus, even a creeping fault is detected at an 
early stage and there is a warning long sold separately in front of a fan failure. 
 

Digitale Interface (in preparation) 

The standard equipment of the power supply is an analog interface. 
Optionally, the unit can be equipped on request with a digital interface. Options 
include either a RS485 interface or a TCP/IP interface. 
 

3D-HD (3D Heat Dissipation)

 

Our aligned and controlled heat dissipation design opens possibilities that are 
formerly being reserved to custom design power supplies: Steplessly hard mount 
of the CPS-EX2000/3000 power supply modules in a 3D-room. 
In practice that means that one can mount the modules into every angle 
imaginable. Our 3D heat dissipation (3D-HD) ensures optimal cooling in each 
mounting position you may consider.

 

 
 

Содержание CPS-EX2000.024

Страница 1: ...value C V monitoring Reference voltage f autonomous programming CSB Current Share Bus Inhibit for safe interlocking Remote Shutdown Sense mode Power Good Relay DC ok Precise dynamics on load change Se...

Страница 2: ...he highest standards of safety and interference suppression The device was developed in accordance with the requirements of IEC CSA UL60950 1 and the EMC standards EN55022 conducted Class B radiated C...

Страница 3: ...ore than 5 seconds in constant current mode to protect a connected defect load The lock can be controlled remotely or repeal by disconnection from the mains again Continuous Mode The unit can be opera...

Страница 4: ...reg 0 5 Ireg 1 Umon 0 5 Imon 1 Uref 1 Temperature Control yes thermal shutdown autorecovery 70 C outside measuring point distance 10mm Hold Up Time 20ms 230Vac mains buffering at full load Inrush Curr...

Страница 5: ...Signal Over Temperature Open Collector 10 TA Output Signal Temperature Alarm Open Collector Early warning 11 OCP Output Signal Over Current Protection Open Collector 12 CC Output Signal Constant Curr...

Страница 6: ...76327 Pfinztal Germany S 6 20 07 2017 01 0 Tel 49 721 46596 0 Fax 49 721 46596 77 www camtec gmbh com info camtec gmbh com Technical changes and errors reserved This product may not be used in life s...

Страница 7: ...may not be used in life support systems CON1 Push In 0 14 1 5mm AWG26 16 CON2 CON3 CON4 DC M8 200A 60 C 250Vac 20A Neutrik PowerCon 3x2 5 mm Neutrik NAC3FCA Copy of the original instruction http www n...

Страница 8: ...s analog linear to the output voltage The monitor signal for current and voltage is the real value that is measured directly at the output of the power supply If a sense line is connected to compensat...

Страница 9: ...n to the polarity of plus and minus of the load to prevent damage to the power supply To avoid interference twist the sense lines In order to reduce inductive effects we recommend that the load lines...

Страница 10: ...S1 0 0 0 0 0 S2 0 1 1 0 0 S2 0 0 0 0 0 S3 0 0 0 1 0 S3 0 0 0 0 0 S4 0 0 1 1 0 S4 0 0 0 0 0 S5 0 1 1 0 0 S5 0 0 0 0 0 S6 1 0 0 0 1 S6 1 1 1 1 1 S7 0 0 0 1 0 S7 0 0 0 0 0 S8 0 1 1 1 0 S8 0 1 1 1 0 S9 0...

Страница 11: ...the soft start the current and the voltage rises within 100ms continuously to the default set values Between the INH contacts applies a current of typical 2mA Warning against damage in case of incorr...

Страница 12: ...for example defective components external feed voltage it is followed by the shutdown of the power output A periodic restart attempts ticker operation period 1s and a message is triggered The alarm si...

Страница 13: ...down OT The alarm signal OT is high when the temperature of the power supply is higher than the over temperature protection threshold Output Open Collector IMAX 10mA VLOW 0 6V VMAX 30V Fan Fail Signal...

Страница 14: ...e can be operated up to a total voltage of 600Vdc in series Due to the dielectric strength of the internal components used only the models with an output voltage of 90Vdc and later are approved for se...

Страница 15: ...mbH Gewerbestra e 30 DE 76327 Pfinztal Germany S 15 20 07 2017 01 0 Tel 49 721 46596 0 Fax 49 721 46596 77 www camtec gmbh com info camtec gmbh com Technical changes and errors reserved This product m...

Страница 16: ...2000Vac 500Vdc 1000Vdc Field Test 2s 2000Vac 2000Vac 500Vdc 1000Vdc 60Vdc 1200Vdc 150Vdc 2100Vdc Type and Factorytest are the manufacturer While repeating test damage can occur to the power supply un...

Страница 17: ...ing IP20 Cooling is achieved via front to rear fans In order to ensure adequate heat dissipation 50mm to the front and 150mm blockade free distance from the device back wall must be guaranteed The har...

Страница 18: ...9 721 46596 77 www camtec gmbh com info camtec gmbh com Technical changes and errors reserved This product may not be used in life support systems 19 48TE Subrack 2U 3U 2U Subrack 48TE for 1 3 CPS EX2...

Страница 19: ...hard mount of the CPS EX2000 3000 power supply modules in a 3D room In practice that means that one can mount the modules into every angle imaginable Our 3D Heat Dissipation 3D HD ensures optimal cool...

Страница 20: ...nting In preparation Safety regulations Please read these instructions completely before using the equipment Keep these instructions on to hand The device may only be operated by trained specialist st...

Отзывы: