LED Operating Signal 

CV/OVP 

CV Constant Voltage Mode LED lights Green 
OVP Overvoltage maloperation or interference voltage LED lights Red 

CC/OCP 

CC Constant Current Mode LED lights Yellow 
OCP Over Current Protection LED flashes Red, also see >>Fuse Mode<< 

TA/OT 

TA Temperature Alarm LED lights Yellow, warning temperature shutdown pending 
OT Over Temperature Shutdown LED lights Red 

INH/FF 

INH Inhibit (Interlock) Shutdown LED lights Yellow 
FF Fan Failure LED lights Red 

SD/SB 

SD Shutdown LED lights Yellow 
SB Standby LED lights Red 

 

Configuration of the Analog Interface 

Mode 

S1 

S2 

S3 

S4 

S5 

S6 

S7 

S8 

S9 

S10 

S11 

S12 

0-5V 

 

 

0-10V 

 

 

0-20mA 

 

 

4-20mA 

 

 

CS active 

 

 

 

 

 

 

 

 

 

 

 

CS non-active 

 

 

 

 

 

 

 

 

 

 

 

Fuse Mode 

 

 

 

 

 

 

 

 

 

 

 

Continuous Mode 

 

 

 

 

 

 

 

 

 

 

 

Warning!

 

CS (Current Share Mode) only applies, when a current distribution must take place while parallel 

operation mode. In single or parallel operation without the need of CS, always switch CS with S11 to OFF=1. 
Factory set: 0-10V Programming / CS non-active (S11=1), Continuous Mode (S12=1) 

 

Programming/Monitoring V/C Analog Interface (Ureg-IN/Ireg-IN) (Umon/Imon) 

The standard programming of the CPS-EX Series is an analog interface. The output voltage is linearly 
proportional to the adjusted analog control signal.  
 
The monitor signal is analog linear to the output voltage. The monitor signal for current and voltage is the real 
value that is measured directly at the output of the power supply. If a sense line is connected to compensate for 
the voltage drop across the load lines, the monitor signal is exactly the value that is measured at the connection 
point of the sense line. The description of the power supply in the sense operation is carried out in a separate 
section. 
The analog inputs and outputs are non-floating. The mass is connected to the DC negative output. 
 
The adapter provides the ability to select the desired input / output via a DIP switch. The burden of the control 
voltages is 1M

Ω

. The burden of the current interface is 500

Ω

. The latency to full compensation of V/C on the 

interface from 0-100% is 15ms for all CPS-EX models. 

 

Programming V/C via Potentiometer (Uadj/Iadj) – Stand Alone Operation 

The power supply is equipped with 2 potentiometers Uadj and Iadj for setting voltage and current.  
To enable the setting on the potentiometer, configure the interface via the DIP switch for 0-5V. Connect each 
Uadj and Iadj of CON3 to the inputs Ureg-IN and I reg-IN. If one of the two potentiometer is not used, the other 
value can still be programmed via the interface. In such case, only the control signal 0-5V can be used. 

 

Fuse Mode  

The Fuse Mode can be used mode to prevent a major damage to a defective load. Fuse Mode can be activated 
via the associated switch S12 DIP switch. 
If the device is in the Fuse Mode (DIP switch S12=0), the device switches off when the constant current 
operation is taking longer than typ. 5s. The red OCP LED flashes with a period of 0,4s. The PSU is locked. The 
interlock can be canceled by the power supply is either switched off by the mains input, SB or SD contact for a 
moment. 

 

Содержание CPS-EX2000.024

Страница 1: ...value C V monitoring Reference voltage f autonomous programming CSB Current Share Bus Inhibit for safe interlocking Remote Shutdown Sense mode Power Good Relay DC ok Precise dynamics on load change Se...

Страница 2: ...he highest standards of safety and interference suppression The device was developed in accordance with the requirements of IEC CSA UL60950 1 and the EMC standards EN55022 conducted Class B radiated C...

Страница 3: ...ore than 5 seconds in constant current mode to protect a connected defect load The lock can be controlled remotely or repeal by disconnection from the mains again Continuous Mode The unit can be opera...

Страница 4: ...reg 0 5 Ireg 1 Umon 0 5 Imon 1 Uref 1 Temperature Control yes thermal shutdown autorecovery 70 C outside measuring point distance 10mm Hold Up Time 20ms 230Vac mains buffering at full load Inrush Curr...

Страница 5: ...Signal Over Temperature Open Collector 10 TA Output Signal Temperature Alarm Open Collector Early warning 11 OCP Output Signal Over Current Protection Open Collector 12 CC Output Signal Constant Curr...

Страница 6: ...76327 Pfinztal Germany S 6 20 07 2017 01 0 Tel 49 721 46596 0 Fax 49 721 46596 77 www camtec gmbh com info camtec gmbh com Technical changes and errors reserved This product may not be used in life s...

Страница 7: ...may not be used in life support systems CON1 Push In 0 14 1 5mm AWG26 16 CON2 CON3 CON4 DC M8 200A 60 C 250Vac 20A Neutrik PowerCon 3x2 5 mm Neutrik NAC3FCA Copy of the original instruction http www n...

Страница 8: ...s analog linear to the output voltage The monitor signal for current and voltage is the real value that is measured directly at the output of the power supply If a sense line is connected to compensat...

Страница 9: ...n to the polarity of plus and minus of the load to prevent damage to the power supply To avoid interference twist the sense lines In order to reduce inductive effects we recommend that the load lines...

Страница 10: ...S1 0 0 0 0 0 S2 0 1 1 0 0 S2 0 0 0 0 0 S3 0 0 0 1 0 S3 0 0 0 0 0 S4 0 0 1 1 0 S4 0 0 0 0 0 S5 0 1 1 0 0 S5 0 0 0 0 0 S6 1 0 0 0 1 S6 1 1 1 1 1 S7 0 0 0 1 0 S7 0 0 0 0 0 S8 0 1 1 1 0 S8 0 1 1 1 0 S9 0...

Страница 11: ...the soft start the current and the voltage rises within 100ms continuously to the default set values Between the INH contacts applies a current of typical 2mA Warning against damage in case of incorr...

Страница 12: ...for example defective components external feed voltage it is followed by the shutdown of the power output A periodic restart attempts ticker operation period 1s and a message is triggered The alarm si...

Страница 13: ...down OT The alarm signal OT is high when the temperature of the power supply is higher than the over temperature protection threshold Output Open Collector IMAX 10mA VLOW 0 6V VMAX 30V Fan Fail Signal...

Страница 14: ...e can be operated up to a total voltage of 600Vdc in series Due to the dielectric strength of the internal components used only the models with an output voltage of 90Vdc and later are approved for se...

Страница 15: ...mbH Gewerbestra e 30 DE 76327 Pfinztal Germany S 15 20 07 2017 01 0 Tel 49 721 46596 0 Fax 49 721 46596 77 www camtec gmbh com info camtec gmbh com Technical changes and errors reserved This product m...

Страница 16: ...2000Vac 500Vdc 1000Vdc Field Test 2s 2000Vac 2000Vac 500Vdc 1000Vdc 60Vdc 1200Vdc 150Vdc 2100Vdc Type and Factorytest are the manufacturer While repeating test damage can occur to the power supply un...

Страница 17: ...ing IP20 Cooling is achieved via front to rear fans In order to ensure adequate heat dissipation 50mm to the front and 150mm blockade free distance from the device back wall must be guaranteed The har...

Страница 18: ...9 721 46596 77 www camtec gmbh com info camtec gmbh com Technical changes and errors reserved This product may not be used in life support systems 19 48TE Subrack 2U 3U 2U Subrack 48TE for 1 3 CPS EX2...

Страница 19: ...hard mount of the CPS EX2000 3000 power supply modules in a 3D room In practice that means that one can mount the modules into every angle imaginable Our 3D Heat Dissipation 3D HD ensures optimal cool...

Страница 20: ...nting In preparation Safety regulations Please read these instructions completely before using the equipment Keep these instructions on to hand The device may only be operated by trained specialist st...

Отзывы: