LED Operating Signal
CV/OVP
CV Constant Voltage Mode LED lights Green
OVP Overvoltage maloperation or interference voltage LED lights Red
CC/OCP
CC Constant Current Mode LED lights Yellow
OCP Over Current Protection LED flashes Red, also see >>Fuse Mode<<
TA/OT
TA Temperature Alarm LED lights Yellow, warning temperature shutdown pending
OT Over Temperature Shutdown LED lights Red
INH/FF
INH Inhibit (Interlock) Shutdown LED lights Yellow
FF Fan Failure LED lights Red
SD/SB
SD Shutdown LED lights Yellow
SB Standby LED lights Red
Configuration of the Analog Interface
Mode
S1
S2
S3
S4
S5
S6
S7
S8
S9
S10
S11
S12
0-5V
0
0
0
0
0
1
0
0
0
0
0-10V
0
1
0
0
1
0
0
1
1
1
0-20mA
1
1
0
1
1
0
0
1
1
1
4-20mA
1
0
1
1
0
0
1
1
1
1
CS active
0
CS non-active
1
Fuse Mode
0
Continuous Mode
1
Warning!
CS (Current Share Mode) only applies, when a current distribution must take place while parallel
operation mode. In single or parallel operation without the need of CS, always switch CS with S11 to OFF=1.
Factory set: 0-10V Programming / CS non-active (S11=1), Continuous Mode (S12=1)
Programming/Monitoring V/C Analog Interface (Ureg-IN/Ireg-IN) (Umon/Imon)
The standard programming of the CPS-EX Series is an analog interface. The output voltage is linearly
proportional to the adjusted analog control signal.
The monitor signal is analog linear to the output voltage. The monitor signal for current and voltage is the real
value that is measured directly at the output of the power supply. If a sense line is connected to compensate for
the voltage drop across the load lines, the monitor signal is exactly the value that is measured at the connection
point of the sense line. The description of the power supply in the sense operation is carried out in a separate
section.
The analog inputs and outputs are non-floating. The mass is connected to the DC negative output.
The adapter provides the ability to select the desired input / output via a DIP switch. The burden of the control
voltages is 1M
Ω
. The burden of the current interface is 500
Ω
. The latency to full compensation of V/C on the
interface from 0-100% is 15ms for all CPS-EX models.
Programming V/C via Potentiometer (Uadj/Iadj) – Stand Alone Operation
The power supply is equipped with 2 potentiometers Uadj and Iadj for setting voltage and current.
To enable the setting on the potentiometer, configure the interface via the DIP switch for 0-5V. Connect each
Uadj and Iadj of CON3 to the inputs Ureg-IN and I reg-IN. If one of the two potentiometer is not used, the other
value can still be programmed via the interface. In such case, only the control signal 0-5V can be used.
Fuse Mode
The Fuse Mode can be used mode to prevent a major damage to a defective load. Fuse Mode can be activated
via the associated switch S12 DIP switch.
If the device is in the Fuse Mode (DIP switch S12=0), the device switches off when the constant current
operation is taking longer than typ. 5s. The red OCP LED flashes with a period of 0,4s. The PSU is locked. The
interlock can be canceled by the power supply is either switched off by the mains input, SB or SD contact for a
moment.