Technical Data Table 

AC Input Range 

184 – 265Vac 

AC Input Frequency 

47 – 63Hz 

DC Input Range 

250 – 350Vdc 

AC Nominal Voltage 

230Vac <10A 

DC Nominal Voltage 

250Vdc <9.3A  350Vdc <6.7A 

Model CPS-EX2000 

.024 

.036 

.048 

.072 

.110 

DC Vout programmable 

24-30Vdc 

30-45Vdc 

45-58Vdc 

58-90Vdc 

90-150Vc 

DC Cout programmable 

42-84A 

28-56A 

21-42A 

14-28A 

9,1-18,2A 

Over Voltage OVP 

35Vdc 

52Vdc 

68Vdc 

105Vdc 

175Vdc 

Ripple Noise  

230Vac 20MHz

 

35mVpp 

50mVpp 

75mVpp 

150mVpp 

300mVpp 

Axiliary Voltage 

12Vdc/0,5A accuracy ±0,5V R&N 30mVpp, not influenced from SB, SD, INH operations 

Continuous Power P

nom

 

184 – 265Vac, 2400W 

Power Density 

8W / Cubic-Inch 

Cooling 

Continuously controlled and monitored fans from EBM Papst (Germany) 

Efficiency 

typ. 92 - 94% 230Vac at full load  

Power Factor Control (PFC)  0,99 / 230Vac full load 
Short Circuit Resistance 

yes 

Open Circuit Protected 

yes 

Base Load (OCP) 

Non required (open circuit protected) 

Load Regulation 

< ± 0,05% 0-100% 

Load Regulation Time 

<1ms on load switch 10-100% 

Rise Time and Latency 

0V – Vout

max

, 15ms over all 

Accuracy 

Ureg: 

 ± 0,5%, Ireg: 

 ± 1%, Umon: 

 ± 0,5%, Imon: 

 ± 1%, Uref: 

 ±1% 

Temperature Control 

yes, thermal shutdown & autorecovery (+70°C, outside measuring point distance 10mm) 

Hold Up Time 

>20ms 230Vac

 

mains buffering at full load 

Inrush Current 

<14,6Aeff <20,7Apeak 230Vac active electronic inrush protection (no simple NTC) 

Startup Delay 

typ. 1s 

Softstart 

typ. 100ms 

Ambient Temperature 

- 20°C…+60°C operating, derating 2,5%/°C >50°C 

Storage Temperature 

- 40°C…+85°C 

Ambient Conditions 

Humidity 95% non-condensing @ 25°C, climate class 3K3, pollution degree 2 

ROHS 

2011/65/EU conform 

REACH 

EG No. 1907/2006 conform 

EMI 

EN55022 conducted class B, radiated class A 

EMS 

EN61000-6-2,3 

Safety 

cUL60950  (design is conform = UL classified), IEC/EN60950-1, IEC/EN60204-1 

Saftey Class I 

VDE0805, VDE0100 

Isolation Input to Output 

3000Vac 

Isolation Input to Case 

2500Vac 

Isolation Output to Case 

500Vdc , 

60Vdc= 1200Vdc / 

150Vdc= 2100Vdc 

MTBF (IEC61709) 

419000h (Meantime Between Failures: statistic time between failures after repairs) 

MTTF (IEC61709) 

146105h (Meantime To Failure: statistic time to ever fails) 

Dimensions (HxWxD) 

84x126,4x444mm | 3,3x5x17,5 Inch (without frontplate, note cable outlet in planning) 

Weight 

4,4kg 

Input Power Connections 

Neutrik NAC3FCA (locked by bajonett) included 

Output Power Connections 

Brass-Powerbars with metric M8 thread, a touch protection is included 

 

Programming Time Vout [ms] 

Model CPS-EX2000

 

.012

 

.024

 

.036

 

.048

 

.072

 

.110 

.220 

Slew Rate 90-10%, 10/100% Load, [ms] typ. 

tba

 

78/7,8

 

tba

 

52/5,3

 

tba

 

tba

 

39/3,9

 

Output Capacity, [mF] typ. 

tba

 

21,6

 

tba

 

3,6

 

tba

 

tba

 

0,11

 

 

 

Содержание CPS-EX2000.024

Страница 1: ...value C V monitoring Reference voltage f autonomous programming CSB Current Share Bus Inhibit for safe interlocking Remote Shutdown Sense mode Power Good Relay DC ok Precise dynamics on load change Se...

Страница 2: ...he highest standards of safety and interference suppression The device was developed in accordance with the requirements of IEC CSA UL60950 1 and the EMC standards EN55022 conducted Class B radiated C...

Страница 3: ...ore than 5 seconds in constant current mode to protect a connected defect load The lock can be controlled remotely or repeal by disconnection from the mains again Continuous Mode The unit can be opera...

Страница 4: ...reg 0 5 Ireg 1 Umon 0 5 Imon 1 Uref 1 Temperature Control yes thermal shutdown autorecovery 70 C outside measuring point distance 10mm Hold Up Time 20ms 230Vac mains buffering at full load Inrush Curr...

Страница 5: ...Signal Over Temperature Open Collector 10 TA Output Signal Temperature Alarm Open Collector Early warning 11 OCP Output Signal Over Current Protection Open Collector 12 CC Output Signal Constant Curr...

Страница 6: ...76327 Pfinztal Germany S 6 20 07 2017 01 0 Tel 49 721 46596 0 Fax 49 721 46596 77 www camtec gmbh com info camtec gmbh com Technical changes and errors reserved This product may not be used in life s...

Страница 7: ...may not be used in life support systems CON1 Push In 0 14 1 5mm AWG26 16 CON2 CON3 CON4 DC M8 200A 60 C 250Vac 20A Neutrik PowerCon 3x2 5 mm Neutrik NAC3FCA Copy of the original instruction http www n...

Страница 8: ...s analog linear to the output voltage The monitor signal for current and voltage is the real value that is measured directly at the output of the power supply If a sense line is connected to compensat...

Страница 9: ...n to the polarity of plus and minus of the load to prevent damage to the power supply To avoid interference twist the sense lines In order to reduce inductive effects we recommend that the load lines...

Страница 10: ...S1 0 0 0 0 0 S2 0 1 1 0 0 S2 0 0 0 0 0 S3 0 0 0 1 0 S3 0 0 0 0 0 S4 0 0 1 1 0 S4 0 0 0 0 0 S5 0 1 1 0 0 S5 0 0 0 0 0 S6 1 0 0 0 1 S6 1 1 1 1 1 S7 0 0 0 1 0 S7 0 0 0 0 0 S8 0 1 1 1 0 S8 0 1 1 1 0 S9 0...

Страница 11: ...the soft start the current and the voltage rises within 100ms continuously to the default set values Between the INH contacts applies a current of typical 2mA Warning against damage in case of incorr...

Страница 12: ...for example defective components external feed voltage it is followed by the shutdown of the power output A periodic restart attempts ticker operation period 1s and a message is triggered The alarm si...

Страница 13: ...down OT The alarm signal OT is high when the temperature of the power supply is higher than the over temperature protection threshold Output Open Collector IMAX 10mA VLOW 0 6V VMAX 30V Fan Fail Signal...

Страница 14: ...e can be operated up to a total voltage of 600Vdc in series Due to the dielectric strength of the internal components used only the models with an output voltage of 90Vdc and later are approved for se...

Страница 15: ...mbH Gewerbestra e 30 DE 76327 Pfinztal Germany S 15 20 07 2017 01 0 Tel 49 721 46596 0 Fax 49 721 46596 77 www camtec gmbh com info camtec gmbh com Technical changes and errors reserved This product m...

Страница 16: ...2000Vac 500Vdc 1000Vdc Field Test 2s 2000Vac 2000Vac 500Vdc 1000Vdc 60Vdc 1200Vdc 150Vdc 2100Vdc Type and Factorytest are the manufacturer While repeating test damage can occur to the power supply un...

Страница 17: ...ing IP20 Cooling is achieved via front to rear fans In order to ensure adequate heat dissipation 50mm to the front and 150mm blockade free distance from the device back wall must be guaranteed The har...

Страница 18: ...9 721 46596 77 www camtec gmbh com info camtec gmbh com Technical changes and errors reserved This product may not be used in life support systems 19 48TE Subrack 2U 3U 2U Subrack 48TE for 1 3 CPS EX2...

Страница 19: ...hard mount of the CPS EX2000 3000 power supply modules in a 3D room In practice that means that one can mount the modules into every angle imaginable Our 3D Heat Dissipation 3D HD ensures optimal cool...

Страница 20: ...nting In preparation Safety regulations Please read these instructions completely before using the equipment Keep these instructions on to hand The device may only be operated by trained specialist st...

Отзывы: