Draining the condensate
In certain conditions, installations in unconditioned space or having long
horizontal or vertical runs may accumulate condensate.
Condensate is known to be acidic; refer to local, state (provincial) or federal
codes for proper handling methods.
In order to prevent condensate from draining back into the water heater, we
recommend a condensate trap and drain to be installed in a horizontal vent
section as close as practical to the water heater vent connection.
Not following proper condensate procedures will void warranty.
Installing the CA686M tankless water heater
Vent Termination Clearancesfor Non-direct Vent Installations in the Us and Canada