To ensure proper operation of the water heater, the following water pressure
guidelines should be followed:
●
Operation of the water heater requires the minimum water pressure of 14 psi
and a minimum water flow rate of 0.75 gpm.
●
Additional water pressure is required for long pipe runs and outlet fitting(s)
water pressure drops.
● To maintain proper performance, ensure suffi Required Water Pressure = Min.
Operating Water Pressure (14 psi) + Pipe Pressure Loss + Faucet and Shower
Pressure Loss + Safety Margin (more than 5 psi).
● To supply hot water to upper floors, additional water pressure (0.44 psi/ft) must
be ensured.The measurement should be calculated by the distance between
the water inlet of the water heater (ground level) to the hot water faucet (upper
floor level).
● Well water systems should be set at a range of 50-60 psi.
● When the water is supplied from a water supply tank, the height of the tank
and the diameter of the pipes and their relation to water pressure, should be
taken into consideration. Gravity water pressure is not recommended.
NOTICE:
If the water flow resistance of a shower head is too high, the burner in
the water heater will fail to ignite. Keep the shower head clean from debris that
could cause additional pressure drop.
NOTICE:
If using mixing valves on the outlet, choose one which prevents cold
water pressure from overcoming hot water line pressure.
IMPORTANT:
Do not apply heat to the HOT or COLD water connections. Any
heat appliedtothe water supply fittings will permanently damage the internal
components of the water heater.
CAUTION: This water heater must only be used with the following water
supply system conditions:
● With clean, potable water free of corrosive chemicals, sand, dirt, or other
contaminates.
● With inlet water temperatures above 32°F, but not exceeding 120°F.
● Free of lime and scale deposits.
● DO NOT reverse the hot and cold water connections. The water heater
will not operate.