background image

Leak testing

       WARNING: 

Never use an open flame to test for gas leaks, as property 

damage, personal injury, or death could result.
The water heater and its gas connections must be leak tested at normal operating 

pressures before it is placed in operation.

●  Turn on the gas shut-off valve(s) to the water heater.

●  Use a commercial leak detector or soapy water solution to test for leaks at all 

    connections and fittings. Bubbles indicate a gas leak that must be corrected.
All connections should also be leak tested after the water heater is placed in 

operation.

Pressure testing the gas supply system

       WARNING: Install a gas pressure regulator, in the gas supply line, 

which does not exceed the maximum supply pressure. DO NOT use an 

industrial type gas regulator.

The water heater must be isolated from the gas piping system by closing the 

manual gas shut-off valve during any pressure testing of the gas supply piping at 

pressures equal to or less than 1/2 psi (14’w.c.).

High altitude

Ratings of gas appliances are based on sea level operation and need not be 

changed for installations at elevations up to 2,000 feet. Unit not recommended for 

elevations in excess of 2,000 feet.

Installing the CA686M tankless water heater

       DANGER:

 Failure to install the vent adapter and properly vent the water 

heater to the outdoors as outlined in the Venting section of this manual will result 

in unsafe operation of the water heater causing death, serious injury, explosion, or 

fire. To avoid the risk of fire, explosion,or asphyxiation from carbon monoxide, 

NEVER operate the water heater unless it is properly vented and has adequate

air supply for proper operation as outlined in the Venting section of this manual.

       WARNING: 

Use UL approved Category III Stainless Steel vent material only. 

No other vent material is permitted.

Owner must refer to vent manufacturer’s instructions and specifications. Z-Flex 

information can be found at www.novaflex.com, see page 48 for additional links.

1

42

Visit Us: Camplux.com

[email protected]

3330-A Marathon Ct Charleston, SC 29418

1(844) 538-7475

Содержание CA686M-LP

Страница 1: ...CAMPLUX 26L Residential Indoor Outdoor Tankless Gas Water Heater USE CARE MANUAL Optional Colour White Grey Visit Us Camplux com support camplux com 3330 A Marathon Ct Charleston SC 29418 1 844 538 7475 ...

Страница 2: ......

Страница 3: ... the Installer WA686M NG WA686M LP WA686MG NG WA686MG LP CA686M NG CA686M LP CA686MG NG CA686MG LP WARNING If the information in these instructions is not followed exactly a fire or explosion may result causing property damage personal injury or death Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliances WHAT TO DO IF YOU SMELL GAS Do no...

Страница 4: ...825 Btu per gallon This is based on a 100 F temperature rise and a nominal specific heat for water of 8 25 Btu per gallon per degree F ANSI Z21 10 3 CSA4 3 2019 SUITABLE FOR WATER POTABLE HEATING ONLY 150 PSI 199 000 23 000 8 0 w c 2 0Kpa 13 0 w c 3 23Kpa 5 66 w c 1 41Kpa For customer service on this appliance contact support camplux com 1 844 538 7475 Maximum Input Rating Btu per hour Minimum Inpu...

Страница 5: ... c 3 23Kpa 5 94 w c 1 48Kpa Category Ill Water Heater For customer service on this appliance contact support camplux com 1 844 538 7475 Maximum Input Rating Btu per hour Minimum Input Rating Btu per hour Minimum Input Gas Pressure Maximum Input Gas Pressure Manifold Pressure Maximum Working Pressure Serial CA686M 120 Volts 60 Hz Less than 12 Amperes Amps Recovery Rating Not recommended in excess o...

Страница 6: ...these operations If you don t understand these instructions or any terms within it seek professional advice Any questions regarding the operation maintenance service or warranty of this water heater should be directed to the seller from whom it was purchased If additional information is required refer to the section on If You Need Service Do not destroy this manual Please read carefully and keep i...

Страница 7: ...s supplier or fire department You re All Set Thanks for purchasing your new Camplux 26L residential tankless water heater This convenient safe and high efficiency product will open the doors to enjoying endless hot water We highly suggest you take the time to read through all of the safety and installation procedures in this manual before attempting to install your new residential water heater Alw...

Страница 8: ... These words mean DANGER An imminently hazardous situation that will result in death or serious injury WARNING A potentially hazardous situation that could result in death or serious injury and or damage to property CAUTION A potentially hazardous situation that may result in minor or moderate injury NOTICE Attention is called to observe a specified procedure or maintain a specific condition Warni...

Страница 9: ...or asphyxiation from carbon monoxide never operate this water heater unless it is installed properly and has an adequate air supply for proper operation Be sure to inspect the flue terminal for proper installation at initial start up and at least annually thereafter Refer to the Care and Cleaning section of this manual for more information regarding flue terminal inspection WARNING Gasoline as wel...

Страница 10: ... ignite flammable vapors Vapors 1 Cannot be seen 2 Are heavier than air 3 Go a long way on the floor 4 Can be carried from other rooms to the main burner flame by air Read and follow water heater warnings and Instructions If owners manual is missing contact the retailer or manufacturer Installation Do not Install water heater where flammable products will be stored or used unless the main burner f...

Страница 11: ...n To find water temperature being delivered turn on a hot water faucet and place a thermometer in the water stream and read the thermometer 120 F Water Temperature Time To Produce a Serious Burn More than 5 minutes 1 1 2 to 2 minutes About 30 seconds About 10 seconds Less than 5 seconds Less than 3 seconds About 1 1 2 seconds About 1 second Time Temperature Relationship in Scalds 125 F 130 F 135 F...

Страница 12: ... to diminish in intensity can also hide or camouflage a gas leak Always check with commercial leak detector or soapy water Gas detectors are recommended in LP and natural gas applications and their installation should be in accordance with the detector manufacturer s recommendations and or local laws rules regulations or customs Water heaters utilizing LP gas are different from natural gas models ...

Страница 13: ...s been made the leak is corrected and a qualified agency has determined the area to be safe WARINING For your safety the information in this manual must be followed to minimize the risk of fire or explosion electric shock or to prevent property damage personal injury or loss of life For installations in the state of california California Law requires that residential water heaters must be braced a...

Страница 14: ...r servicing should be referred to a qualified technician READ AND FOLLOW THIS SAFETY INFORMATION CAREFULLY Save these instructions This water heater must be installed in accordance with these instructions local codes utility company requirements and or in the absence of local codes use the latest edition of the American National Standard National Fuel Gas Code A copy can be purchased from either t...

Страница 15: ...se to the most frequently used outlet and its position chosen with safety and service in mind Make sure people particularly children disabled and elderly will not touch the hot water outlet or the flue terminal The flue terminal and air inlet must be clear of obstruction and shrubbery If installed in a public corridor please assure that the surrounding area is free of debris obstruction and flamma...

Страница 16: ...OT install water heater where subject to vibrations DO NOT install the water heater in Recreational Vehicles Mobile Homes Boats and other Watercraft DO NOT install the water heater near vents for heating or cooling A minimum of 4 feet should be maintained If the clearances stated on the Instruction Warning Label located on the front panel of the heater differ install the water heater according to ...

Страница 17: ...lants from common spray cans or gas leaks from A C and refrigeration equipment are highly corrosive after passing through a flame The water heater warranty is voided when failure of the heater is due to operation in a corrosive atmosphere Inspect shipment Inspect the water heater for possible damage Check the markings on the rating plate of the water heater to be certain the type of gas supplied c...

Страница 18: ...take precedent over these instructions Installing The WA686M Tankless Water Heater Typical Installation Some Items May Not Apply 1 16 Visit Us Camplux com support camplux com 3330 A Marathon Ct Charleston SC 29418 1 844 538 7475 Expansion Tank If Needed To Hot Water Faucet S Pressure Relief Valve Drain Valve Discharge Line To Suitable Drain Manual Gas Appliance Shut Off Supplied Check Valve Or Bac...

Страница 19: ...water filter Be sure to connect the water inlet and the hot water outlet as shown on the water heater If reversed the water heater will not function Installation of unions or flexible copper connections are recommended on the HOT and COLD water lines so that the water heater may disconnect easily for servicing if necessary Install a Check Valve between the water heater and the water shutoff valve ...

Страница 20: ...e to the water heater should be clean black steel pipe or other approved gas piping material A ground joint union or ANSI design certified semi rigid or flexible gas appliance connector should be installed in the gas line close to the water heater The National Fuel Gas Code NFGC mandates a manual gas shut off valve See NFGC for complete instructions If flexible connectors are used the maximum leng...

Страница 21: ...the relief valve and the water heater Discharge from the relief valve should be piped to a suitable drain to eliminate potential water damage Piping used should be of a type approved for the distribution of hot water Hot and cold water lines should be insulated up to the water heater The discharge line must be NO SMALLER than the outlet of the valve and must pitch downward to allow complete draina...

Страница 22: ...O NOT use an industrial type gas regulator Failure to isolate heater during pressure test can damage internal components voiding warranty The water heater and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at testy pressures in excess of 1 2 psi The water heater must be isolated from the gas piping system by closing th...

Страница 23: ...a gas leak that must be corrected The factory connections should also be leak tested after the water heater is placed in operation High altitude Ratings of gas water heaters are based on sea level operation and need not be changed for installations at elevations up to 2 000 feet Unit not recommended for elevations in excess of 2 000 feet Installing the water heater Flue outlet location The locatio...

Страница 24: ...o deck or too close to shrubbery as flue gases or condensate vapor may become a nuisance or hazard and may cause property damage Condensate vapor could cause damage and be detrimental to the operation of regulators relief valves or other equipment To help prevent moisture from freezing on walls and under eaves do not locate vent terminal on the side of a building with prevailing winter winds The w...

Страница 25: ...eas where chemical agents such as thinner benzine and alkaline are used Avoid areas of direct sunlight The MAXIMUM distance between the water heater and the remote control s installation location is limited to 50 feet No other manufacturer s controls are suitable for use with this water heater DO NOT attempt to disassemble the remote control Remote Control connection Installation and Set For Panel...

Страница 26: ...tlet wires of connector Installation of remote control 1 Remove the front cover of the Remote Control See illustration below 2 At installation site mark and screw four holes with 0 24 with 1 2 depth Insert 4 rubber screws into the holes Place the remote control against the wall align the holes of control with the holes in the wall and fasten them with wood thread screws See illustration below Remo...

Страница 27: ...of an electric leakage breaker is recommended GFCI Keep any excess of the power supply cord on the outside of the water heater If local codes require hardwiring see instructions for Hardwiring the Electrical Connections WARNING Shock hazard line voltage is present Before servicing the water heater turn off the electrical power to the water heater at the main disconnect or circuit breaker Failure t...

Страница 28: ...e to the white neutral wire CAUTION Label all wires prior to disconnection when servicing controls Wiring errors can cause improper and dangerous operation Verify correct operation after servicing Electric Wiring Diagram WIFI A Ground Wire Thermostat Panel Display Indoor Fan Remote Control Outdoor Ignition Pin Feedback Wire Water Flow Sensor Water Ratio Valve Temp Sensor of Water Inlet Temp Sensor...

Страница 29: ... authorized by the manufacturer into onto or in conjunction with the water heater The use of unauthorized energy saving devices may shorten the life of the water heater and may endanger life and property The manufacturer disclaims any responsibility for such loss or injury resulting from the use of such unauthorized devices Pipe Installation Inlet Pipe and Outlet Pipe Installation Use pressure res...

Страница 30: ...on the rating plate DO provide adequate air for combustion and ventilation as discussed in the Use Care Manual and the National Gas Code DO maintain proper clearances to combustibles as specified by applicable code DO ensure that the flue terminal location complies with the guidelines found in the Use Care Manual and National Fuel Gas Code Don t s DON T block or restrict Air Intake Opening located...

Страница 31: ... heater unit tighten the expansion screws and put 2 wood thread screws into the bottom holes When being installed directly on carpeting the water heater shall be installed on a metal or wood panel extending beyond the full width and depth of the water heater by at least 3 in 76 2 mm in any direction or if the water heater is installed in an alcove or closet the entire floor shall be covered by the...

Страница 32: ...eter of the pipes and their relation to water pressure should be taken into consideration Gravity water pressure is not recommended NOTICE If the water flow resistance of a shower head is too high the burner in the water heater will fail to ignite Keep the shower head clean from debris that could cause additional pressure drop NOTICE If using mixing valves on the outlet choose one which prevents c...

Страница 33: ...ight and free of leaks Water filter is clean and in place Materials used are as instructed in this manual Water pipes are insulated C Gas Supply Gas type matches rating plate Gas supply pressure is sufficient fo rthe water heater Gas line equipped with shut off valve union and sediment trap Approved pipe joint compound used Commercial leak detector or soap and water solution used to check all conn...

Страница 34: ... 2 The terminal must be at least 1 64 ft away from obstruction and must be well vented Vent pipe should slope 3 downward to avoid condensing water and protect from rain entering Vent pipe should avoid direct strong wind because the downdraft will cause malfunction The water heater should be installed far from any blockage and with plenty of space for installation and maintenance Adequate clearance...

Страница 35: ...es and their thinners solvents or removers Raising the water heater will reduce BUT NOT eliminate the possibility of lighting the vapor of any flammable liquids which may be improperly stored or accidentally spilled If the water heater is installed in a garage it should be installed so that the direct ignition system and main burner are no less than 18 inches above the garage floor Hot and cold wa...

Страница 36: ... the ceiling The minimum net free area of each opening must not be less than one square inch per 1 000 BTUH of the total input rating of all the appliances in the enclosure but not less than 100 square inches if each opening communicates with other unconfined areas inside the building Buildings of unusually tight construction shall have the combustion and ventilation air supplied from outdoors or ...

Страница 37: ...hemicals often contain such halogenated hydrocarbons An air supply containing halogenated hydrocarbons may be safe to breathe but when it passes through a gas flame corrosive elements are released that will shorten the life of any gas burning appliance Propellants from common spray cans or gas leaks from A C and refrigeration equipment are highly corrosive after passing through a flame The water h...

Страница 38: ...take precedent over these instructions Installing The CA686M Tankless Water Heater Typical Installation Some Items May Not Apply Expansion Tank If Needed To Hot Water Faucet S Drain Valve Discharge Line To Suitable Drain Manual Gas Appliance Shut Off Supplied Check Valve Or Backflow Preventer Pressure Refief Valve 1 36 Visit Us Camplux com support camplux com 3330 A Marathon Ct Charleston SC 29418...

Страница 39: ...ct to the water inlet then check water flow Close the shutoff valve and clean the water filter If a water heater is installed in a closed water supply system such as one having a backflow preventer in the cold water supply line means shall be provided to control thermal expansion Contact the water supplier or local plumbing inspector on how to control this situation CAUTION This water heater must ...

Страница 40: ...the pipes and their relation to water pressure should be taken into consideration Gravity water pressure is not recommended IMPORTANT Do not apply heat to the HOT or COLD water connections Any heat applied to the water supply fittings will permanently damage the internal components of the water heater NOTICE If the water flow resistance of a shower head is too high the burner in the water heater w...

Страница 41: ...e with a different type of gas other than the type shown on the rating plate Such conversion could result in hazardous operating conditions Please have a professional connect the gas pipe The supplied Manual Gas Appliance Shutoff Valve must be installed at the gas connection of the water heater at the time of installation see diagram to the left The branch gas supply line to the water heater shoul...

Страница 42: ...e on male threads only Relief valve A new pressure relief valve complying with the Standard for relief Valves and Automatic Gas Shut Off Devices for Hot Water Supply Systems ANSI Z21 22 must be installed at the hot water outlet connection of the water heater at the time of installation Local codes shall govern the installation of relief valves For safe operation of the water heater be sure that Th...

Страница 43: ...and pressure relief valve should be installed the manufacturer recommends a type 40XL Watts T P relief valve or an equivalent model be used NOTICE Manual operation of relief valves should be performed at least once a year Turn off the electrical power and gas shutoff valve Lift and release lever on the relief valve and check the manual operation of the relief valve You should take precaution to av...

Страница 44: ...o or less than 1 2 psi 14 w c High altitude Ratings of gas appliances are based on sea level operation and need not be changed for installations at elevations up to 2 000 feet Unit not recommended for elevations in excess of 2 000 feet Installing the CA686M tankless water heater DANGER Failure to install the vent adapter and properly vent the water heater to the outdoors as outlined in the Venting...

Страница 45: ...nt termination must be used The termination should be a 90 elbow type with screen Refer to page 48 Use a vent pipe with an antidisconnection structure The use of a High Temperature Silicone 500 F may be required to seal vent connections To prevent accidental gas exhaust leakage apply a 1 4 wide bead approximately 1 4 from the end and another bead against the joint side of the stop bead Follow vent...

Страница 46: ...s to venting One 1 of these openings should be close to where the vent pipe enters the ceiling The other opening should be near the vent termination A ventilation hole with a 16 sq in opening should be made at least every 10 feet NOTICE Vent pipes must be completely insulated with inflammable material when installed in alcoves closets and garages and must not touch any flammable material 1 4 Per F...

Страница 47: ...t pipe in horizontal runs is toward the top of the installation see illustration to the left Venting lengths Maximum vent length Owner must refer to vent manufacturer s instructions and specifications Z Flex information can be found at www novaflex com please refer to page 48 for additional links The system will not operate if there is excessive restriction pressure drop in the venting system A ma...

Страница 48: ...the water heater we recommend a condensate trap and drain to be installed in a horizontal vent section as close as practical to the water heater vent connection Not following proper condensate procedures will void warranty Installing the CA686M tankless water heater Vent Termination Clearancesfor Non direct Vent Installations in the Us and Canada Vent Terminal V Air Supply Inlet Area Where Termina...

Страница 49: ...or balcony Clearance to window or door that may be opened 4ft 1 2m below or to side of opening 1ft 300mm above opening 4ft 1 2m below or to side of opening 1ft 300mm above opening 3ft 91cm above if within 10ft 3m horizontally Clearance to permanently closed window Vertical clearance to ventilated soffit located above the terminal within a horizontal distance of 2 feet 61cm from the center line in ...

Страница 50: ...facturer s instructions and specifications by visiting www novaflex com Installation guidelines for venting is provided by NovaFlex who is solely responsible for venting installation accuracy Z Flex Installation Instructions https www novaflexgroup com information_centre zflex 02Z Vent 20Special 2 0Gas 20Vent 20System 05Z Vent 20Dimensional 20Specifications 202018 pdf 1 48 Visit Us Camplux com sup...

Страница 51: ...n Termination Elbow 3 in x 90 Termination Hood Part 2ZVWB03 2SVSWTF03 2SVSWTEF03 2SVEVWC03 2SVEDWCF03 2SVEPWCF03 Description Horizontal Vent Kit Horizontal Wall Thimble Horizontal Wide Wall Thimble Vertical Drain Tee Horizontal Drain Pipe Vent Pipe Part 2SVSTEX0390 Part 2SVSHTX03 49 Visit Us Camplux com support camplux com 3330 A Marathon Ct Charleston SC 29418 1 844 538 7475 ...

Страница 52: ... UL approved Category III vent material only No other vent material is permitted Owner must refer to vent manufacturer s instructions and specifications Z Flex information can be found at www novaflex com refer to page 48 for additional links CAUTION Follow the vent manufacturers installation instructions as design might vary om manufacturer to manufacturer 1 50 Visit Us Camplux com support camplu...

Страница 53: ...stall any remote control outdoors Place remote control s out of children s reach The remote control s can be installed in convenient locations such as the kitchen laundry room or utility room 1 4 Per Feet Downward Slope 6 Clearance 2 Max Typical Horizontal Termination w 1 4 Per Feet Downward Slope Support Hanger Vent Adapter 250 mm 250 mm To Drain Dispose of Condensate in Accrdance to Local Codes ...

Страница 54: ...te Control Connection Installation and Set For Panel Control Remote Control and Remote Control units Panel Control Remote Control and Remote Control units will work with either one or two remote controls If two remotes are desired a wire connector will need to be provided To connect the remote control 1 For one control Plug the aviation joint into the socket directly on the water heater see illust...

Страница 55: ...en them with wood thread screws See illustration below 3 Replace the front cover on the remote control WARNING Field wiring connections and electri cal grounding must comply with local codes or in the absence of local codes with the la test edition of the National Electrical Code ANSI NFPA 70 Wood Thread Screw 102mm 4 02 83mm 3 27 4 Ф0 24 Base of Control Remote Control Front Cover Installation Hol...

Страница 56: ...g should be carried out by a qualified electrician in accordance with local codes The water heater requires 120 VAC 60Hz and should be properly grounded DO NOT connect grounding wire to water pipes gas pipes telephone cables lightning conductor circuits and to grounding circuit of other equipment that carry a ground fault interrupter An ON OFF switch must be provided and installed for the incoming...

Страница 57: ...ith the kit must be carefully followed Insulation blankets available to the general public for external use on gas water heaters are not necessary The purpose of an insulation blanket is to reduce the standby heat loss encountered with storage tank heaters This water heater does not store water making an insulation blanket unnecessary The manufacturer s warranty does not cover any damage or defect...

Страница 58: ...alve Cold Water Pipe Drain Valve Inlet Water Pipe Hot and cold pipe insulation installation For increased energy effciency use pipe insulation Please install the insulation according to the illustrations above making sure to insulate all the way to the top Do not cover any drain or pressure valve s NOTICE The hot and cold pipes should be insulated as shown help to provide additional freeze protect...

Страница 59: ...where standing water may occur Mounting the CA686M Tankless Water Herter Make sure the location of the water heater allows for easy access and operation In case of dry wall or concrete wall use dry wall anchors or lag bolts The water heater requires 120VAC 60Hz Have a receptacle with ground terminal near the water heater The length of the power supply cord is 5 feet Drill the holes as per the size...

Страница 60: ... the expansion screws go into the holes of the water heater Screw the nuts tight pay attention to the direction of the elbow B Side ins tallation 1 Aim the holes in the water heater onto the expansion screws hang it up and screw the nuts tightly 2 Put the vent pipe through the holes in the wall and connect the elbow with the water heater and vent pipe C Vertical installation Please refer to local ...

Страница 61: ...ght and free of leaks Water filter is clean and in place Materials used are as instructed in this manual Water pipes are insulated C Gas Supply Gas type matches rating plate Gas supply pressure is sufficient for the water heater Gas line equipped with shut off valve union and sediment trap Approved pipe joint compound used Commercial leak detector or soap and water solution used to check all conne...

Страница 62: ...n the gas control knob Never use tools If the knob will not push in or turn by hand don t try to repair it call a qualified service technician Force or attempted repair may result in a fire or explosion D DO NOT use this water heater if any part has been under water Immediately call a qualified service technician to inspect the water heater and to replace any part of the control system and any gas...

Страница 63: ...derstanding or following the Operating Instructions or the Care and Cleaning section it is recommended that a qualified person or serviceman perform the work DO turn off manual gas shut off valve if water heater has been subjected to over heating fire flood physical damage or if the gas supply fails to shut off DO NOT turn on water heater unless water and gas supplies are fully opened DO NOT turn ...

Страница 64: ...g hot and cold water in branch water lines Procedures for adjusting the thermostat for energy efficient operation at the minimum water temperature setting consistent with the consumer s needs Contact a licensed plumber or the local plumbing authority for further information Water Temperature Setting DANGER There is a hot water scald potential if the temperature is set too high Households with smal...

Страница 65: ...r heater is in use or has water flow the display will read the actual temperature To view the set temperature in this condition press UP or DOWN and the set temperature will flash for 3 seconds The hottest temperature water will be at the hot water faucet closest to the water heater Always remember to test the water temperature with your hand before use and remember that hotter water increases the...

Страница 66: ...y be hot enough to create a scald hazard The water should be released into a suitable drain to prevent injury or property damage DANGER Hotter water increases the potential for Hot Water Scalds DANGER Failure to perform the recommended Routine Preventative Maintenance can harm the proper operation of this water heater which can cause carbon monoxide dangers excessive hot water temperatures and oth...

Страница 67: ...Keep water heater area clear and free from combustible materials gasoline and other flammable vapors and liquids Ensure the unit has not been damaged If damage or denting is present contact a service personnel to verify proper operation Check for any abnormal sounds during normal operation of the water heater All piping should be checked for gas and or water leaks Refer to page 21 42 of this manua...

Страница 68: ...nect the power supply Vacuum around the water heater for dust dirt and lint on a regular basis Clean the water heater and remote control by using a damp soft cloth with a few drops of mild detergent and gently wiping the surfaces of the unit Wipe any remaining moisture with a dry soft cloth To ensure sufficient ventilation and combusttion air supply proper clearances must be maintained The water f...

Страница 69: ...dequately protected from freezing Units with Anti Freezers have an automatic heating device and will help to avoid freeze damage but the power must be kept on Freezing will occur with no power In very cold areas and when the temperature is under 32 F or in event of an ice storm freezing will occur as the heating power limit is exceeded If these conditions take place please follow the procedures ex...

Страница 70: ...r is coming out of all hot water faucets Care and Cleaning of the Outdoor Model Water Heater Draining the water heater Model WA686M Expansion Tank If Needed To Hot Water Faucet S Drain Valve Discharge Line To Suitable Drain Manual Gas Appliance Shut Off Supplied Check Valve Or Backflow Preventer Pressure Refief Valve WARNING Failure to follow these instructions while draining the water heater can ...

Страница 71: ... valve NOTICE The water heater may not operate unless the above procedure is followed correctly Care and Cleaning of the Indoor Model Water Heater Draining the water heater Model CA686M WARNING Failure to follow these instructions while draining the water heater can cause serious damage to the water heater as well as personal injury including scalding Expansion Tank If Needed To Hot Water Faucet S...

Страница 72: ...ts This step is to remove air from the water lines 10 Reconnect the breaker and turn the on off switch to the ON position fully open the gas shut off valve and the water shut off valve NOTICE The water heater may not operate unless the above procedure is followed correctly Before You Call For Service Troubleshooting tips Save time and money Review the charts on the following pages first and you ma...

Страница 73: ...proper power is being supplied and or water supply is adequate Turn the unit ON by the button on the remote control Increase the temperature setting Check and replace if necessary See instructions for Error Code and if required contact a dealer for service Increase the temperature setting Check and open the gas valve fully Decrease the temperature setting Allow more water to flow Clean the filter ...

Страница 74: ...ockage C4 F2 Cold water inlet temperature sensor failure Residual flame failure C1 Turn off the hot water faucet or turn off the switch on the display or remote control Turn off the hot water faucet or turn off the switch on the display or remote control Turn off the hot water faucet or turn off the switch on the display or remote control Replace the water inlet temperature sensor Connect the wate...

Страница 75: ...ING For your safety DO NOT attempt to disassemble this unit for any reason Model WA686M 1 1 2 3 4 5 6 7 8 4 9 12 13 14 15 16 17 18 19 21 22 23 20 25 27 28 24 26 10 1 29 30 73 Visit Us Camplux com support camplux com 3330 A Marathon Ct Charleston SC 29418 1 844 538 7475 ...

Страница 76: ...s Inlet Connection Water Inlet Connection Assembly Power Line Back Cover Assembly Front Cover Assembly Remote control panel Sealing gasket Power Supply Board Thermostat Chimney Set Thermal Fuse Electric heating antifreezing unit Right Ignition Needle Thermostat Heating Exchange Burner Assembly Gas Distributor Axis Assembly Gas Distributor Axis Assembly Water outlet Temperature Sensor Water Proport...

Страница 77: ...For your safety DO NOT attempt to disassemble this unit for any reason Model CA686M 11 24 1 2 3 4 5 6 7 8 4 9 12 13 14 15 16 17 18 19 21 22 23 20 25 27 28 10 26 75 Visit Us Camplux com support camplux com 3330 A Marathon Ct Charleston SC 29418 1 844 538 7475 ...

Страница 78: ...t Connection Water Inlet Connection Assembly Power Line Back Cover Assembly Front Cover Assembly Display panel Export paster Power Supply Board Thermostat Chimney Set Thermal Fuse Electric heating antifreezing unit Right Ignition Needle Thermostat Heating Exchange Burner Assembly Gas Distributor Axis Assembly Gas Distributor Axis Assembly Water outlet Temperature Sensor Water Proportional Valve Wa...

Страница 79: ...ING WITHOUT LIMITATION AS TO MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE WITH RESPECT TO ANY GOODS SOLD HEREUNDER BUYER S EXCLUSIVE REMEDY IS LIMITED TO REPAIR OR REPLACEMENT OF THE GOODS SOLD AT CAMPLUX S DISCRETION CAMPLUX SHALL NOT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES Limited Warranty Period This Warranty is extended by Camplux Systems to the Owner This warranty takes effec...

Страница 80: ...utside of the continental US After the first 30 days of purchase the customer is responsible for all shipping to Camplux regardless of reason or circumstance The method for warranty related shipping will be Ground equivalent with the provider of Camplux s choosing AK HI and any location outside of the continental US will be responsible for all shipping costs regardless of reason or circumstance Al...

Страница 81: ...f such defect malfunction or failure to conform to this Warranty In order to make a claim under this Warranty The Owner must notify Camplux of the failure of the Product to conform to this Warranty Under this Warranty Camplux Systems will only provide replacement parts as described in the Limited Warranty Period The Owner will be responsible for any cost incurred including labor costs for servicin...

Страница 82: ...Camplux Systems by any other part for damages of any kind including but not limited to incidental and consequential damages arising out of the subject matter of this Agreement Some States do not allow exclusion or limitation of incidental or consequential damages so the above limitatio or exclusion may not apply to you This warranty gives you specific legal rights You may also have other rights th...

Страница 83: ......

Страница 84: ...Visit Us Camplux com support camplux com 3330 A Marathon Ct Charleston SC 29418 1 844 538 7475 ...

Отзывы: