NOTICE:
If the duct openings which supply combustion and ventilation air are to
be covered with a protective screen or grill, the net free area (openings in the
material) of the covering material must be used in determining the size of the
openings. Protective screening for the openings MUST NOT be smaller than 1/4”
to prevent clogging by lint or other debris.
Corrosive atmospheres
The air in beauty shops, dry cleaning establishments, photo processing labs, and
storage areas for liquid and powdered bleaches or swimming pool chemicals
often contain such halogenated hydrocarbons.
An air supply containing halogenated hydrocarbons may be safe to breathe, but
when it passes through a gas flame corrosive elements are released that will
shorten the life of any gas burning appliance.
Propellants from common spray cans or gas leaks from A/C and refrigeration
equipment are highly corrosive after passing through a flame.
The water heater warranty is voided when failure of the heater is due to operation
in a corrosive atmosphere.
NOTICE:
The water heater should not be installed near any air supply containing
halogenated hydrocarbons.
Check the unit
Inspect the water heater for possible damage. Check the markings on the rating
plate of the water heater to be certain the type of gas supplied corresponds to the
water heater requirements. Verify all included parts are present (Check details
from In The Box at Page 32)
Water supply connections
Plumbing should be carried out by a qualified plumber in accordance with local
codes. Use approved plumbing materials and tools only.
Install a check valve between the water heater and the water shut off valve.