8. Use only mild soapy water, other cleaners may damage the surface of the
water heater.
9. DO NOT remove any label including the rating plate while cleaning or servicing.
NOTICE:
DO NOT block or obstruct the air intake opening located at the lower left
corner of the water heater. A minimum of 12″ is required between this combustion
air inlet opening and any obstruction.
Venting system inspection
The venting system should be inspected annually to ensure all of the vent
sections are secure and airtight.
It is recommended that qualified service personnel familiar with Category III
venting inspect the venting system.
Check vent connection joint sections with a solution of soapy water to assure air
tightness while the unit is operating. Bubbles around a joint connection indicates a
seal leak. Refer to page 18 for vent sealing instructions.
DO NOT operate the unit if vent system shows signs of leaking exhaust.
Check to make sure that the air intake and the vent terminal have not been
blocked or contain debris.
Vacation and extended shut-down
If the water heater is to remain idle for an extended period of time, the power and
water to the appliance should be turned off.
The water heater and piping should be drained if they might be subjected to
freezing temperatures.
After a long shut-down period, the water heater’s operation and controls should
be checked by qualified service personnel.
Not Equipped With Anti-freezing Protection
Draining procedure
When
the temperature falls below 32°F(0°C), water in your plumbing system or
water heater can turn to ice and then expand causing damage to the water heater.
This damage is not covered under your manufacturer’s warranty. If these
conditions are anticipated, please drain the water heater as follows to help but not
guarantee from freezing: