The water heater must be isolated from the gas piping system by closing the
manual gas shut off valve during any pressure testing of the gas supply piping at
pressure equal to or less than 1/2 PSI (14’ w.c.).
For Using Under High Altitude
Ratings of gas appliance are based on sea level operation and need not be
changed for installations at
elevations up to 2,000 feet/600 meter. Unit not recommended for elevations in
excess of 2,000 feet/600 meter.
Mounting The Water Heater
Make sure the location of the appliance allows for easy access and operation.
In case of dry wall or concrete wall use dry anchors or lad bolts.
The water heater requires 120VAC/60Hz. Have a receptacle with ground
terminal near the water heater. The length of the power supply cord is 5 feet.
Drill the holes as per sizes in the figure to the left, put 2 expansion screws into the
top holes, and 2 rubber screws into the bottom holes.
CAUTION:
Reinforcement of the wall is required in case the wall is not strong
enough to hold the appliance.
4.64″
23.23″
3.54″
Installation Holes For Flue
Installation Holes
Φ
3.94″
4-
Φ
0.4″deep 2″
3.54″