10. Click Apply to save the changes. Verify the settings in the summary window.
(Recommended) Save a copy of the settings to a file on the computer. Click OK.
11. Click Disconnect and close Device Configuration Utility.
8.2.1.2 Set up LoggerNet
The LoggerNet Network Map is configured from the LoggerNet Setup screen.
NOTE:
Setup has two options, EZ (simplified) and Standard. Click on the View menu at the top of
the Setup screen, and select Standard view.
From the LoggerNet toolbar, click Main > Setup and configure the Network Map as described in
the following steps:
1. Select Add Root > IPPort.
2. Select PakBusPort and pbRouter for PakBus data loggers such as the CR6 or CR1000X.
NOTE:
PakBus data loggers include the following models: GRANITE-series, CR6, CR3000,
CR1000X, CR800-series, CR300-series, CR1000, and CR200(X)-series.
3. Add a data logger to the pbRouter.
4. From the Entire Network, on the left side, select the IPPort. Enter the Konect PakBus Router
DNS address and port number as noted in the Konect PakBus Router setup (
(p. 32)). Enter them into the Internet IP Address field in the format DNS:Port
with a colon separating DNS and Port. For example, axanar.konectgds.com:pppp where
pppp is the port number.
8. Cellular communications option
35