The following image illustrates a simple application wherein a C terminal configured for digital
input, and another configured for control output are used to control a device (turn it on or off)
and monitor the state of the device (whether the device is on or off).
In the case of a cell modem, control is based on time. The modem requires 12 VDC power, so
connect its power wire to a data logger SW12 terminal. The following code snip turns the modem
on for the first ten minutes of every hour using the
TimeIsBetween()
instruction embedded
in an
If/Then
logic statement:
If TimeIsBetween
(0,10,60,Min)
Then
SW12
(1)
'Turn phone on.
Else
SW12
(0)
'Turn phone off.
EndIf