Advanced Graphic Data Manager
Installation
9
3.3.2
Panel mounting, Installation dimensions
Fig. 3:
Panel mounting and installation dimensions. All dimensions in mm or (inch)
• Installation depth without terminal cover: approx. 158 mm (6.22") (incl. terminals and fastening
clips)
• Installation depth with terminal cover: approx. 197 mm (7,76")
• Panel cutout: 138
+1
x 138
+1
mm (5.43
+0.04
x 5.43
+0.04
")
• Panel thickness: 2 to 40 mm (0.08 to 1.58")
• Max. viewing angle range: from the display central axis 50° in all directions
• Securing to DIN 43 834
1.
Push the unit through the panel cutout from the front. To avoid heat accumulation, we
recommend keeping a distance of >15 mm (>0.59 inch) from the walls and other units.
2.
Hold the unit horizontally and then hang the two jack screws into the openings (either as
shown in figure 3 the upper opening on the left and the lower opening on the right side of the
housing, or use the openings on top and bottom of the housing).
3.
Tighten the screws on the jack screws equally with a screwdriver such that a secure seal to the
control panel is guaranteed (dynamometric screwdriver: 100 Ncm).
107.1 (4.22)
27
(1.06)
8.77
(0.3)
58
(0.28)
196 (7.72)
20
(0.79)
158 (6.22)
157.4 (6.20)
192.3 (7.57)
37.07
(1.46)
149.2
(5.87)
195.2
(7.69)
5
(0.2)
141 (5.55)
138
(5.43
)
+1
+0.04
138 (5.43)
138
(5.43)
Содержание LINAX A325