Wiring
Advanced Graphic Data Manager
12
4.1.3
Auxiliary voltage output as transmitter power supply for 2-wire
sensors
Fig. 5:
Connecting the auxiliary voltage output when using as transmitter power supply for 2-wire sensors in the
current measuring range
– External display: e.g. Loop-powered indicator
– Sensor 1: e.g. Temperature field transmitter
– Sensor 2: e.g. Digital pressure transmitter
_
+
-
Y
+
-
Y
+
+
_
24 V Out: max. 250 mA
On connecting channels 3-16
see terminal connections Ch1-2
Sensor 1
Sensor 2
External display
(optional)