Page
16
- Manual:
FA00458-EN
- vers.
1
- 04/2017 - © C
AME S.p.A. - The data and information shown in this manual ar
e t
o be consider
ed as subject t
o change at any time and without the need for any advance warning.
ENGLISH
OUTPUTS
OUTPUTS 12
*
MODIF.OUTPUT 001
OUTPUT 01
▲
TYPE 001
STABLE
▼
*
▼
▲
▼
▲
+ -
▼
▲
PULSE TIME 001
[0..255] SEC 000
+ -
ARMING DELAY 001
[0..255] SEC 000
+ -
DISARM DELAY 001
[0..255] SEC 000
+ -
Status: (Default:
STABLE
)
S
A
STABLE
the output's activity follows the status of the associated event
Example: the output is activated by the associated input being in
an OPEN condition
PULSE
The activity of the output is determined by the associated event
but only for a certain time, the duration of which can be selected
Parameter visible only if the output is the pulse type
Activation duration: (Default:
000
)
S
A
Duration time of pulse output activation
|-----------
-------------|
Activation duration
Example: you want to open a door lock with a code Associate a pulse output with an acti-
vation time of 3 seconds with a code
Parameter visible only if the output is the stable type
Activation delay: (Default:
000
)
S
A
Delay time between the activation command and the output’s activation
Deactivation delay: (Default:
000
)
S
A
Delay time between the deactivation command and the output’s deactivation
|---
--|
|---
----|
Delay Activ.
Delay Deactiv.
STATUS
EXIT
COMMAND
EXIT
Example: you want to view the on/off status of the system via an output In the Output As-
sociation menu assign the areas' switch-on status to an output programmed as stable and
with zero second delays on activation and deactivation