CMD ON OUTP. 001
ALWAYS
+ -
ON OPERATION 001
PULSE SWITCH ON
*
DESCRIPTION 001
DESCRIPTION 001
*
Output command: (Default:
ALWAYS
)
S
A
Depending on this parameter, managing the output can be linked to whether the input is on
or off
ALWAYS
The output is always commanded by the status of the input To be
more precise: the output is activated if the input is unbalanced and
reset if the input is balanced
ARMED
If the input is active, or one or more areas associated with it are
armed, the output is commanded by the status of the input To be
more precise: the output is activated if the input is unbalanced and
reset if the input is balanced
NOT ARMED
If the input is deactivated, or no area associated with it is armed,
the output is commanded by the status of the input To be more
precise: the output is activated if the input is unbalanced and reset
if the input is balanced
Parameter visible only if the input is an arming one
Arming: (Default:
PULSE SWITCH ON
)
F
S
A
Lets you manage the type of arming/disarming operation on the areas of the control unit
associated with the input
PULSE SWITCH ON
When the input is unbalanced the control unit arms the areas
PULSE SWTCH OFF
When the input is unbalanced the control unit disarms the areas
PULSE ON+OFF
When the input is unbalanced the control unit reverses the on/off
status of the areas associated with the input
STABLE ON+OFF
The on/off status of the areas associated with the input follows the
input's balancing status If the input is unbalanced the areas are on,
if the input is balanced, the areas are off Example: see the example
shown for the type of input defined as
ARMING
Input description:
F
S
A
Lets you edit the description of the input