ACTIVATING
RESTORING
DESCRIPTION 2
CAUSE
Telephone notifications group
Alarm
Sabot
age
Technical
Burglar
y
Arming
Failure
Code
Ke
y
Entrance
Various
RADIO.MOD.TMP xx
MODULE DESCR.
The tamper device on the radio receiver
module on bus xx has been tampered with.
Check module tamper.
X
KYP TAMP.ALRM xx
KEYPAD DESCR.
The tamper device on keypad xx has been
tampered with. Check keypad tamper.
X
EXIT TEC.MENU
Exiting the technical menu is recorded in
the events memory.
BATTERY FAIL. xx
REST. BATTERY xx
SECURITY ALARM
PWR.DESCR.
Control unit battery failure.
X
LOCAL CONN.
The communication between the control
unit and PC (uploading - downloading of
programming and events) is recorded in
the events memory.
REMOTE CONN.
The remote communication between the
control unit and PC (uploading - download-
ing of programming and events) is record-
ed in the events memory.
POWER DOWN xx
REST. POWER xx
SECURITY ALARM
PWR.DESCR.
Fault of no 230 V AC power supply to con-
trol unit.
X
AUTO TEST
The autotest is normally used to check
whether the control unit is up and running
via a telephone communication.
X
CODE N. xxx
CODE DESCR.
Entering a code (user or technical) is re-
corded in the events memory.
X
KEY N. xxx
KEY DESCR.
The action of approaching a key to a read-
er is recorded in the events menu.
X
SYSTEM FAIL.
RST.SYST.FAIL
Generic system failure notification. The
failure might be caused by batteries, 230V
power supply, power supply unit or fuses).
X
SYST.TEC.ALRM.
RST SYS T.ALR
Generic technical alarm event. It is gener-
ated with an area technical alarm (if an area
is not associated to a technical input, the
system technical alarm is not triggered).
X
GEN.SYS.ALA.
RST G.S. ALRM
The generic general alarm event is trig-
gered by either an area alarm or a system
tamper alarm.
X X
PWR UNIT FAIL. xx
SECURITY ALARM
PWR.DESCR.
Notification of power supply unit - control
unit fuses failure.
X
REBOOT C.U.
The event is logged when the control unit
is powered up for the first time or it is reset
(the restart button is pressed on the con-
trol unit's board).
SYS SBTG ALRM
RST SYS SBTG
Generic notification of a tamper alarm
(sabotage).
X
AREA SBTG ALR xx RST A-S-ALRM xx
AREA DESCR.
When an input goes into tamper alarm
mode the associated areas do so as well.
All tamper-type events which are not as-
sociated with any inputs automatically
trigger a tamper alarm of area 1.
X
REMOTE CONTROL XX
REMOTE CONTROL
DESCR.
Each time you use the system's remote
control, it is recorded in the events mem-
ory.
RMT.ENT.CODE xxx
CODE DESCR.
Entering a code (user) remotely (by voice
guide or SMS) is recorded in the events
memory.
X
TECH ALRM xx
RST TECH ALRM xx
AREA DESCR.
When an input goes into technical alarm
mode the associated areas do so as well.
X
BURGLAR ALRM xx
RST BRGL ALRM
AREA DESCR.
When an input goes into burglary alarm
mode the associated areas do so as well.
X
COD.ENABLE xxx
CODE DESCR.
Code xxx has been activated from the user
menu. The
CODE N. xxx
chronologi-
cally previous event shows who modified it.