Events messaging

Events are made up of:
•  TIME and DATE
•  EVENT DESCRIPTION (activation / restoration)
•  EVENT INDEX NUMBER
•  EVENT DESCRIPTION (part 2)

ACTIVATING

RESTORING

DESCRIPTION 2

CAUSE

Telephone notifications group

Alarm

Sabot

age

Technical

Burglar

y

Arming

Failure

Code

Ke

y

Entrance

Various

ARMING

 

TOTAL

Areas on

There is an arming event when the only 

operations are (total or partial) arming. 

When arming all of the areas managed by 

the control unit, the second description 

will read TOTAL, whereas for partial arm-

ing the areas on will be shown (example 

##--#).

X

PARTIALIS.

 

Areas on

There is a partialisation event when there 

are operations of non-total disarming 

of areas (partial disarming). The second 

description will show the on/off status 

of the remaining areas (example ##--#).

X

DISARMING

There is a disarming event when the sys-

tem is totally off.

X

TAMPER xx ALRM.

RST, TAMPER xx

SECURITY ALARM

PWR.DESCR.

Tampering with an opening or a viola-

tion at the control unit or an auxiliary 

power supply unit has been detect-

ed. Check the integrity and the tamper.

X

ALA.INP.TAMP. xxx RES.INP.TAMP. xxx

INPUT DESCR.

Input xxx has been tampered with (ei-

ther cut or short-circuited depending 

on the balancing). Check the integri-

ty of the input's electricity line. Even 

if it has restored itself "on its own", 

check the input's electricity line be-

cause there could still be faulty contacts.

X

AREA ALARM  xx

AREA ALRM RST xx

AREA DESCR.

When an input goes into alarm mode so do 

the associated areas.

X

INP. ALARM xxx

RESTORE INPUT xxx

INPUT DESCR.

Input xxx has gone into alarm mode (it has 

been unbalanced).

X

BATTERY TX xxx

INPUT DESCR.

Radio input xxx's battery is dead. Replace 

it as soon as possible.

X

KYP.COM.ERR. xx

KEYPAD DESCR.

Keypad xx is no longer communicating 

with the control unit (red communication 

LED on keypad not flashing). Check activa-

tion of keypad, bus cabling, address.

X

IN-MOD. ERR. xx

MODULE DESCR.

The inputs expansion module on bus xx is 

no longer communicating with the control 

unit (red communication LED on module 

not flashing). Check activation of module, 

bus cabling, dip switch address.

X

OUT-MOD. ERR. xx

MODULE DESCR.

The outputs expansion module on bus xx is 

no longer communicating with the control 

unit (red communication LED on module 

not flashing). Check activation of module, 

bus cabling, dip switch address.

X

RADIO.MOD.ERR. xx

MODULE DESCR.

The radio receiver module on bus xx is no 

longer communicating with the control 

unit (red communication LED on module 

not flashing). Check activation of module, 

bus cabling, dip switch address.

X

RADIO MOD.JAM. xx

MODULE DESCR.

The radio receiver module on bus xx has 

detected a radio transmission that could 

block any radio transmitters (JAMMING 

function activated on control unit).

X

TX SUPERVIS. xxx

INPUT DESCR.

Radio input xx has transmitted a per-

son-detected communication.

IN-MOD.T-ALRM xx

MODULE DESCR.

The tamper device on the inputs expansion 

module on bus xx has been tampered with. 

Check module tamper.

X

OUT-MOD.T-ALM xx

MODULE DESCR.

The tamper device on the outputs expan-

sion module on bus xx has been tampered 

with. Check module tamper.

X

Содержание PXC08

Страница 1: ...SECURITY ALARM CONTROL UNIT PROGRAMMING MANUAL PXC08 FA00458 EN...

Страница 2: ...PXLAN PXWEB 6 SCENARIOS 7 AREAS 8 KEYPADS 9 READERS 10 INPUTS 11 OUTPUTS 16 TIMES 18 TELEPHONE NOTIFICATIONS 19 TELEPHONE NOTIFICATIONS 20 ASSOCIATING OUTPUTS 22 CODES 23 KEYS 25 PHONES 26 TELEPHONE O...

Страница 3: ...riendly as possible for inexperienced installers as well as the most demanding profession als the system incorporates the programming mode concept This can provide a few or a lot of programming parame...

Страница 4: ...sors microwave when system is off associated with the BED ROOM area Yields a positive with BEDROOM area off U3 Failure yields a negative when failures are de tected U2 System status yields a negative...

Страница 5: ...ds Default F S A The keypads used must be activated using the keys Example if you intend to use 4 keypads on the system set Readers Default F S A The readers used must be activated using the keys Exam...

Страница 6: ...est F S A The test allows you to manually control the system s outputs Inputs test F S A The test allows you to control the status of the system s inputs RS485 BUS SYSTEM 02 RS485 BUS RS485 SPEED 9600...

Страница 7: ...sed for arming some specific areas for example a scenario that only arms the perimeter area PERIMETER ON SEL AREAS OFF Only the selected areas are disarmed nothing changes with the status of the areas...

Страница 8: ...leave the system with some areas unarmed because some inputs are open In this case the triggering of the alarm will inevitably warn that the system has been left with inputs open Slave Default A The d...

Страница 9: ...areas Scenario 3 CLOSE SHOP SEL AREAS ON areas Keypad 1 Situated in the home associated areas scenario A CLOSE HOME scenario B OPEN HOME scenario C CLOSE SHOP Keypad2 Situatedintheshop associatedarea...

Страница 10: ...reas scenario L1 CLOSE HOME Reader 2 Situated in the shop associated areas scenario L1 CLOSE SHOP Code 1 Owner associated areas Code 2 Employee associated areas Scenarios Default L1 sc 1 L2 sc 2 L3 sc...

Страница 11: ...AILURE It is active whether the control unit is armed or disarmed In the event of an alarm the failure LED comes on the system failure output is activated and the ANOMALY message is displayed on the c...

Страница 12: ...e associated areas switch off Pulse on off When an input is unbalanced the associated areas switch status when they are off they switch on and when on they switch off Stable arm disarm When an input i...

Страница 13: ...PARTIAL ON the input is delayed if all the associated areas are on and is delayed if it is partialised at least one area off and one on Example this parameter is set when you need to have the front d...

Страница 14: ...set using the keys Example two sensors are aimed on the same room and the user wants an alarm to be sig nalled only when both sensors go into alarm mode Input 1 Type IMMEDIATE And input INPUT 2 Input...

Страница 15: ...f the input is deactivated or no area associated with it is armed the output is commanded by the status of the input To be more precise the output is activated if the input is unbalanced and reset if...

Страница 16: ...of which can be selected Parameter visible only if the output is the pulse type Activation duration Default 000 S A Duration time of pulse output activation Activation duration Example you want to op...

Страница 17: ...with POSITIVE SECURITY the relay will normally be energised and will de energise only when the output is activated Remote activation Default NO S A If activated YES it lets you remotely activate the...

Страница 18: ...after replacing the battery carry out a manual BATTERY TEST by accessing the technical menu Power down notification delay Default 060 S A This determines after what period the LACK of GRID voltage is...

Страница 19: ...numbers with the keys Activating and restoring the control unit and bus peripherals sabotage alarm A Telephone notifications associated with the activation and restoration of the control unit s sabot...

Страница 20: ...of the system total arming means the total arming of the areas managed Set the telephone numbers with the keys Arming and disarming single areas A Telephone notifications associated with arming and di...

Страница 21: ...Set the telephone numbers with the keys Entering key S A Telephone notifications associated with entering the key on the reader With select the keys Set the telephone numbers with the keys Activating...

Страница 22: ...glary alarm output Default NO S A For selecting the output to associate with the single area s burglary alarm burglary inputs Area ready output Default NO S A Lets you select the output to associate w...

Страница 23: ...s only allowed when the control unit is totally off no area on AFTER USER CODE Programming the control unit from PC is only allowed when the control unit is totally off no area on and the User code ha...

Страница 24: ...user code to access the user menu Activating user menu heading Armings Default ENABLED A Enables the User Code to access the heading Armings on the User Menu Activating user menu heading Events Defau...

Страница 25: ...ou want to use a key it must be activated Areas associated with the key Default S A Lets you assign the areas of competence of the key Use the keys to set the areas to be associated Key learning F S A...

Страница 26: ...ted to a switchboard with GSM call option 0 C 0 4 5 6 7 8 9 0 1 2 Telephone number Indicates the presence of the switchboard Number to request line from switchboard Telephone communication format Defa...

Страница 27: ...keypad a code key associated with the areas of competence that has the property of disarming areas NONE If an event general technical sabotage etc alarm starts the cycle of telephone calls it CANNOT b...

Страница 28: ...he remote control by GSM and safe GSM you can select the telephone numbers the telephone dialler must answer Activating PSTN line control Default NO A If activated it checks control of the PSTN line I...

Страница 29: ...ch off PREVIOUS STATUS The on off status of the areas goes back to the one preceding Reboot C U Quick arming Default DISABLED A If activated it lets you start scenarios from the keypads without having...

Страница 30: ...d correctly they can give rise to unwanted interventions of the control unit PROGRAMMER 22 PROGRAMME A MODIF ESC PROG AT STEP 01 NEW ESC PROG AT STEP 01 HRS 00 PROG AT STEP 01 MINUTES 00 PROG AT STEP...

Страница 31: ...See User Manual for displaying events Events print out A Press to start printing out the events on the control unit RS 232 CLOCK TIME DATE 25 14 34 05 07 10 A EDIT NO 03 46 01 01 10 YEAR 10 03 46 01...

Страница 32: ...OU SURE A YES ESC ARE YOU SURE A YES ESC ARE YOU SURE A YES ESC RESTORE CODES IN PROCESS RESTORE KEYS IN PROCESS A A A The default parameters do not delete the acquired codes and keys To do that you h...

Страница 33: ...ld still be faulty contacts X AREA ALARM xx AREA ALRM RST xx AREA DESCR When an input goes into alarm mode so do the associated areas X INP ALARM xxx RESTORE INPUT xxx INPUT DESCR Input xxx has gone i...

Страница 34: ...YSTEM FAIL RST SYST FAIL Generic system failure notification The failure might be caused by batteries 230V power supply power supply unit or fuses X SYST TEC ALRM RST SYS T ALR Generic technical alarm...

Страница 35: ...a message received notification or notification of receipt of the KISS OFF package OUTPUT ON XXX Activating an output OUTPUT OFF XXX Deactivating an output PSTN DOWN PSTN RESTORED When the line has b...

Страница 36: ...Italy 33079 Sesto al Reghena Pordenone Italy 39 0422 4940 39 0422 4941 39 0434 698111 39 0434 698434 English Manual code FA00458 EN ver 1 04 2017 CAME S p a The data and information shown in this manu...

Отзывы: